期刊文献+

活性污泥工艺模型在计算机模拟中的建立与应用 被引量:2

Establishment and application of computer simulated model of activated sludge process
下载PDF
导出
摘要 利用计算机技术模拟活性污泥生化过程是分析研究污水处理工艺的有效手段之一,模拟的有效性取决于采用的动力学模型、工艺模型、沉淀模拟以及模拟计算中的数学分析方法。其中工艺模型反映了工艺特性,是真实工艺在模拟过程中的再现。根据水力学及运行特征,可将现有主要工艺分为单池间歇式、多池间歇式、单向连续式和交替连续式。运用ASM2D动力学模型,对某污水处理厂的UNITANK工艺进行模拟,结果表明,选择的动力学模型和工艺模型是合适的。 Kinetic model, process model, settler model and mathematical analysis method make effective the computer simulation which is one of the potent ways to analyze and study bio-chemical processes of activated sludge. The process model reflects the property of simulated process and is the reappearance of real process in simulation. Based on hydraulic and operational characteristic, the main current activated sludge processes can be divided into four types namely batching mono-tank, batching multi-tank, continuous mono-directional and continuous reciprocal-direction processes. ASM2D was applied to simulate UNITANK of some WWTP. The results showed that the proper kinetic model and process model were chosen.
出处 《给水排水》 CSCD 北大核心 2006年第9期94-100,共7页 Water & Wastewater Engineering
基金 国家自然科学基金资助项目(50238050)。
关键词 活性污泥工艺 计算机模拟 工艺模型 UNITANK工艺 Activated sludge processes Computer simulation Process model UNITANK process
  • 相关文献

参考文献24

二级参考文献22

  • 1[1]Kappeler J,Gujer W.Estimation of Kinetic parameters of heterotrophic biomass under aerobic conditions and characterization of wastewater for activated sludge modelling[J].Wat Sci Tech,1992,25(6):125-129.
  • 2[2]Ekama G A,Dold P L,Marais G V R.Procedures for determining influent COD fractions and the maximum specific growth rate of heterotrophs in activated sludge systems[J].Wat Sci Tech,1986,18(8):91-114.
  • 3[3]Wanner,Oskar,Kappeler.Calibration of an activated sludge model based on human expertise and on a mathematical optimization technique a comparison,Water Science and Technology Interactions of Wastewater,Biomass and Reactor Configurations in Biological Treatment Plants Proceedings of the IAWPRC Specialised Seminar[J].1991,25(6):21-23.
  • 4[4]Daniel Mamais,David Jenkins,Paul Pitt.A rapid physical-chemical method for the determination of readily biodegradable soluble COD in municipal wastewater[J].Wat Res,1993,27(1):195-197.
  • 5Schutze M, Butler D, Beck M B. Modelling, simulation and control of urban wastewater systems [M]. London: Springer, 2002.
  • 6Hidromantis. GPS-X Technical Reference [M]. Ontario:Hidromantis, Inc. ,1995.
  • 7Printemps C, Baudin A. Optimisation of a large WWTP thanks to mathematical modeling[A]. 9th IWA Specialised Conference on design, operation and economics of large wastewater treatment plants [C]. Prague: Vodni hospodarsvi s. r. o. ,2003.
  • 8Gohle F,Finnson A. Dynamic simulation of sludge blanke movements in a full-scale rectangular sedimentation basin[J]. Wat Sci Tech,1996,33(1): 89-99.
  • 9IWA Task Group on Mathematical Modeling for Design and Operation of Biologica Wastewater Treatment.Activated Sludge Models ASM1,ASM2,ASM2D and ASM3 [M].London:IWA Publishing,2000.
  • 10Wanner O.Calibration of an activated sludge model based on human expertise and on a mathematical optimisation technique-a comparison [J].Wat Sci Tech,1992,25(6):141-148.