中压(6-10kV)感应电动机级联式多电平变频调速的成功应用

Successful Application of Multi-level and Multi-stages Connection Variable Frequency Speed Regulation System for the 10/6 kV Induction Motor in P/P
下载PDF
导出
摘要 明珠电厂173 MVA燃气轮机蒸汽轮机联合循环发电厂余热锅炉(HRSG)汽包供水的给水泵(6kV)以50 Hz额定值运行了8年,2004年12月将给水泵改为变速运行,安装了级联式多电平变频调速装置。并按我厂变频改造特点,用最简单快速的处理,从工频转为变频运行,为我厂带来极大的节电经济效益。特别介绍其移相整流变压器,用硬件固定移相,以载波三角波同步调制。详细介绍各功率单元IGBT的参数,级联多电平变频在我厂应用极其稳定和成功。 The HRSG boiler steam drum water feed pump(6 kV) of the MZ 173 MVA gas turbine-steam turbine combine-cycle power plant has been changed to VVVF running in Dee. 2004, using the multi-stages and multi-level speed regulation system after its first installation 8 years ago. A big economical profit has been made, the properties of the main equipment is analyzed such as the phase-shift and rectifier transformer the IGBT is used in the inverster bridge. The parameter of IGBT is presented in detail. The multi-stage and multi- level speed regulation system is used successfully in the MZ power plant.
机构地区 广州明珠发电厂
出处 《电气传动》 北大核心 2006年第10期60-64,共5页 Electric Drive
关键词 锅炉汽包给水泵 变频 级联多电平 整流 移相 变压器 boiler steam drum water feed pump variable frequency multi-level and multi-stages connection rectifier phase shift transformer
  • 相关文献

参考文献5

  • 1黄俊.半导体变流技术[M].北京:机械工业出版社,1979..
  • 2张燕宾.变频调速应用实践[M].北京:机械工业出版社,2002..
  • 3吴忠智 黄立培 吴加林.调速用变频器及配套设备选用指南[M].北京:机械工业出版社,2003.91-119.
  • 4麦焕材.广州明珠电力集团联合循环发电厂电控DCS之设计原理及设计经验[J].电力自动化产品信息,2000,(10).
  • 5麦焕材.同步电机励磁系统及电子式自动励磁调节器(AVR)的研究和分析.中国科学技术文库1998 ISBN 7-5023-2824-6,1987