摘要 结合工程实例,对公称管径≥500 mm的大管径直埋热水管道的安装方式、设计理论及设计要点进行了探讨,对大管径直埋热水管道的设计、施工提出了建议。只要满足强度和稳定性条件,应优先采用无补偿冷安装方式。在设计时应重点考虑防止局部失稳、加强管件结构及控制管道坡度变化幅度。 The installation mode, design theory and design essentials of directly buried hot-water pipeline with nominal diameter of equal to or greater than 500 mm are discussed, and suggestions on the design and installation of directly buried hot-water pipeline with large diameter are offered. The cool installation mode without expansion should be adopted preferably provided that the conditions of strength and stability are met. Preventing local instability, reinforcing pipeline structure and controlling change amplitude of pipeline slope should be considered importantly in the design.
作者 陈鸣 冯继蓓
出处 《煤气与热力》 2006年第10期46-48,共3页 Gas & Heat
关键词 直埋热水供热管道 大管径 无补偿冷安装 设计 directly buried hot-water heat-supply pipeline large diameter cool installation without expansion design
  • 相关文献

参考文献7

二级参考文献22

  • 1马学军.一次性直埋管道敷设技术[J].工程设计与应用研究,1994(4):27-32. 被引量:3
  • 2梁经通.供热管道直埋技术的发展及应用[J].煤气与热力,1994,14(1):42-43. 被引量:10
  • 3刁乃仁,方肇洪.直埋供热管道L型管段的热补偿及强度验算[J].煤气与热力,1995,15(5):48-52. 被引量:5
  • 4张彩雨.地热直埋管无人工预热可行性分析[J].煤气与热力,1990,(5):58-59.
  • 5陈庭耀.直埋供热管道的优化设计[J].煤气与热力,1988,(3):55-58.
  • 6吴涛.热力管道无补偿直埋敷设技术及其应用[J].煤气与热力,1987,(6):54-58.
  • 7崔孝秉.埋地长输管道热胀内力近似分布[J].力学学报,1984,16(1):1-1.
  • 8穆树芳.实用直埋供热管道技术[M].北京:中国矿业大学出版社,1997..
  • 9兰德劳夫·皮特 贺平.区域供热手册[M].哈尔滨:哈尔滨工程大学出版社,1998..
  • 10-.北京市煤气热力研究所热力管道无补偿直埋敷设的试验研究[J].煤气与热力,1981,(3):52-59.