摘要 针对U型管埋地换热器的传热特点,考虑了两管脚之间的相互影响,建立起非稳态传热模型。采用数值解法对该理论模型进行了求解,并将结果与实验值进行了对比分析,发现两者变化趋势一致,但理论计算结果比实验测试值低,其中的一个重要原因是因为换热器与土壤间的热交换不是纯导热过程,还应该进一步考虑土壤中热湿迁移等因素的影响。 An unsteady heat transfer model was set up and solved by numerical solution for the heat transfer characteristic of U-pipe heat exchanger and the interaction of the two pipe legs of the GSHPs. The theoretic results were compared with the experimental results. Those change trends are similar, but the theoretic results are less than the experimental results. One of the important reasons is that the heat exchange between the heat exchangers and the soil is not pure heat conduction and some factors such as mass transfer in soil should be considered.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2006年第1期63-66,共4页 Acta Energiae Solaris Sinica
关键词 地源热泵 U型管埋地换热器 管脚 数值解法 ground source heat pump(GSHP) U-pipe heat exchanger pipe legs numerical solution
  • 相关文献

参考文献3

二级参考文献6

  • 1方肇洪 刁乃仁 苏登超 等.竖直U型埋管地源热泵空调系统的设计与安装[J].现代空调,2001,(10):101-105.
  • 2Bose J E,Parker J D,McQuiston F C. Design/data manual for closed-loop ground-coupled heat pump systems[M].Atlanta:ASHRAE,1985.
  • 3Kavaragh S P.Ground-source heat pumps[J].ASHARE Journal,1998,40(10).
  • 4Gu Y,O′Neal D L.Development of an equivalent diameter expression for vertical U-tubes used in ground-coupled heat pumps[J].ASHRAE Transactions,1998,104(2):347-355.
  • 5Diao N R,Cui P,Fang Z H.The thermal resistance in a borehole of geothermal heat exchangers[C].Proc.12th International Heat Transfer Conference,2002.
  • 6曾和义,刁乃仁,方肇洪.竖直埋管地热换热器的稳态温度场分析[J].山东建筑工程学院学报,2002,17(1):1-6. 被引量:25