摘要
目的比较铸造桩核粘结后不同间隔时间备牙对冠方微渗漏的影响。方法66颗离体单根管下颌前磨牙,其中60颗随机分为6组,制作铸造桩核。2、4、6组分别于铸造桩核用磷酸锌水门汀粘结2、10、30min后备牙,1、3、5组桩核粘结后不备牙作为对照,其余6颗牙分别作为阴性及阳性对照。所有牙齿经1周染色后,作透明处理,评价冠方微渗漏的情况。结果间隔时间相同的各备牙组与不备牙组的微渗漏差异有统计学意义(P<0.05);不备牙组之间的微渗漏差异无统计学意义(P>0.05);间隔2min和10min备牙组与间隔30min备牙组的微渗漏差异亦有统计学意义(P<0.05)。结论备牙时高速手机产生的震动会明显增加桩冠的冠方微渗漏,桩核粘结后备牙的间隔时间至少为10~30min。
Objective To investigate the effect of coronal microleakage of cemented cast posts and cores after different interval time preparation. Methods Cast posts and cores were fabricated for 60 of 66 extracted single-root mandibular premolars which randomly divided into 6 groups and cemented with zinc phosphate cement. The other 6 specimens acted as negative control group and positive control group. After 2, 10, 30 minutes interval time, preparation would do for preparation groups and three control groups without preparation. After dying and making transparent, the assessment of the coronal microleakage was done. Results The results showed significant differences betwecn each prepared group and unprepared group. No differences were defected in 3 unprepared groups. But significant differences were recorded between after 2, 10 minutes preparation groups and 30 minutes group. Conclusion High-speed preparation had a sign/ficant negative effect on the coronal microleakage of posts. The interval time of preparation after cemented cast trusts and cores was at least between 10 and 30 minutes.
出处
《华西口腔医学杂志》
CAS
CSCD
北大核心
2006年第5期426-428,431,共4页
West China Journal of Stomatology
关键词
铸造桩核
预备
冠方微渗漏
cast posts and cores
preparation
coronal microleakage