摘要 针对变压器冲击试验,提出了中性点电流法、传递函数法和联合时频分析法等3种故障诊断方法。结合具体实例,分别用3种不同的方法对电力变压器进行故障诊断,其中着重介绍了联合时频分析法。通过对3种方法的优缺点进行分析比较,认为联合时频分析法是最先进、准确性最高的方法,具有良好应用前景。 Against transformers impulse tests, the paper presented neutral point current, function of transmission and joint time-frequency analysis methods for fault discrimination. Specific examples of, respectively, using three different methods of power transformers for fault discrimination, which highlights the joint time-frequency analysis. Through analysis of the advantages and disadvantages of three methods comparison, joint time-frequency analysis is considered to be the most advanced and highest accuracy of the method and has good prospects for applications.
出处 《华北电力技术》 CAS 2006年第10期1-4,共4页 North China Electric Power
基金 国家自然科学基金项目(50077013)
关键词 变压器冲击试验 中性点电流 联合时频分析 transformers impulse tests neutral point current joint time-frequency analysis
  • 相关文献

参考文献4

  • 1L.科恩(著),白居宪(译).时-频分析:理论与应用.西安:西安交通大学出版社,1995
  • 2Shie Qian, Dapang Chen. Joint time-frequency analysis methods and applications. Prentice Hall PTR.1983
  • 3Malewski R, Poulin B. Impulse testing of power transformers using the transfer function method. IEEE Trans on Power Delivery,3(2):476 489,Apr. 1988
  • 4傅晨钊,汲胜昌,李彦明,刘杰,王国刚.小波变换用于变压器冲击试验绝缘故障诊断[J].高电压技术,2000,26(5):16-18. 被引量:5