摘要
目的:对清开灵注射液进行内毒素动态浊度法检查实验,建立定量检测清开灵注射液中内毒素实验方法以代替热原检查法,提高内毒素的检出率,避免临床热原反应的发生。方法:采用《中国药典》2000年版附录检测内毒素的动态比浊法。结果:清开灵注射液经10倍及以上倍数释释后,对鲎试刺反应无干扰作用,内毒素回收率在50%-200%范围内。结论:本方法干扰因素小,检测结果准确,可作为日常检测使用。
Objective:To establish the kinetic turbidimetric technique for quality control on endotoxin content in Qingkailing Injection. To set up a reasonable limit of endotoxin for Qingkailing Injection and establish a rapid method for examining endotoxin instead of pyrogen test. Methods :The kinetic turbidimetric technique in Chinese pharmacopoeia 2000 edition was used. Results:Qingkailing Injection did not interfere with limulus test in 1 : 10 dilution,The endotoxin recovery was more than 50 percent and less than 200 percent. Conclusion:This mehod is slight in interference and accurate in detection result,and can be used in routine assay.
出处
《中国药品标准》
CAS
2006年第4期66-68,共3页
Drug Standards of China
关键词
清开灵注射液
内毒素
动态浊度法
鲎试刺
Qingkailing Injection
endotoxin
kinetic turbimetric technique