变电站接地网导体的连接要求稳定可靠,在铜接地网中显得更为重要,本文通过对火泥熔接的介绍,结合工程实例阐明了火泥熔接的特性及优点,并指出材料截面选择的合理性。
The connection of the ground net conductor of substation requires steady and reliable, which seems even more important in the copper ground net. Through introducing the exothermic welding and combining with an instance of project, the characteristic and advantage of exothermic welding was explained, and the rationality of selecting the material section was pointed out.
出处
《湖北电力》
2006年第5期61-62,共2页
Hubei Electric Power
关键词
接地网
火泥熔接
连接
ground net
exothermic welding
connection