期刊文献+

人眼波前像差及准分子激光手术矫正的研究

Study on Measurement of the Wavefront Aberration of the Human Eye and Corneal Refractive Surgery by Excimer Laser
原文传递
导出
摘要 波前像差严重影响了人眼正常的视觉质量,引入Hartm ann-Shack波前传感器可有效地测量人眼的各阶像差,结合自适应光学中Zern ike多项式重建波前的理论。建立人眼波前像差和角膜切削量模型的关系模型,利用准分子激光发射的激光脉冲去除定量的角膜组织,从而改善人眼视觉质量。应用表明,人眼像差测量和由像差引导的准分子激光手术矫正具有明显的临床医学价值。 The qualify of vision of the human eye is affected seriously by the aberration in the eye. The Hartmann - Shack wavefront sensor can been used to calibrate the aberrations of the human eye, and reconstruct the shape of the aberrated wavefront in the pupil of an optical system by fitted the data to a Zernike polynomial series. The relation between the corneal ablation depth and the human eye aberrations had been created. The excimer laser pulses can been used to remove the corneal tissue in order to improve the qualify of the human eye. Our experiments indicate that wavefront aberration guided corneal ablation can reduce wavefront aberrations.
作者 童桂 廖文和
出处 《应用激光》 CSCD 北大核心 2006年第4期275-278,共4页 Applied Laser
基金 江苏省"十五"高技术研究项目(BG2002012) "十五"国家计委产业化项目(计产业[2002]31329)资助
关键词 波前像差 调制传递函数 H-S波前传感器 准分子激光 Wavefront aberration, MTF, H - S wavefront sensor, Excimer laser
  • 相关文献

参考文献10

二级参考文献27

  • 1陈志辉,凌宁,饶学军,王成.人眼像差哈特曼测量仪的重复性测试[J].光电工程,2004,31(6):5-8. 被引量:7
  • 2陆大祥,李楚杰,付咏梅,王华东.甘氨酸对内毒素致热性的抗拮作用研究[J].中国病理生理杂志,1996,12(3):235-238. 被引量:30
  • 3[2]Noll J R. Zernike polynomials and atmospheric turbulence[J]. J. Opt. Soc. Am, 1976, 66(3): 207-211.
  • 4[4]LIANG J, GRIMM B, GOELZ S, et al. Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor[J]. J.Opt. Soc.Am, 1994, A 11(7): 1949-1957.
  • 5Howland H C, Buettner J .Computing high order wave aberration coefficients from variations of best focus for small artificial pupils[J]. Vision Res. 1989, 29: 979-983.
  • 6Liang J, Williams D R .Supemormal vision and high-resolution retinal imaging through adaptive optics[J]. J.Opt. Soc. Am.1997, A 14(11) : 2884-2892.
  • 7Artal P, Marcos S, et al .Odd aberrations and double-pass measurements of retinal image quality[J]. J.Opt. Soc. Am. 1997, A12(2) : 195-201.
  • 8He J C, Marcos S .Measurement of the wave-front aberration of the eye by a fast psychophysical procedure[J]. J.Opt. Soc.Am. 1998, A 15: 2449-2455.
  • 9Prieto P M, Vargas-Martin F .Analysis of the performance of the Hartmann-Shack sensor in the human eye[J], J.Opt. Soc.Am, 2000, A 17(8) : 1388-1398.
  • 10Southwell W H .Wave-front estimation from wave-front slope measurements[J]. J.Opt, Soc. Am, 1980,A 70(8) : 998-1006.

共引文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部