摘要
建立了油炸方便面中丙烯酰胺的气相色谱-质谱联用(GC/MS)内标分析方法。采用柱前溴化衍生的方法,以甲基丙烯酰胺为内标,分别采用GC/ECD、GC/FTD、GC/MS分析测定,在37.5μg/kg加标水平样品回收率范围70.9%~87.6%,平行测定7次相对标准偏差9.8%,标准系列在0~5.00mg/L范围内线性良好。该方法定性、定量准确度均优于气相色谱法,适合于常规油炸方便面中丙烯酰胺的测定。
Acrylamide in fried instant noodle was determined by gas chromatography/mass spectrometry. With the aid of the methyl acrylamide as an internal standard, acrylamide was derivatized through bromination and determined by GC/MS. Multi- method of GC/ECD, GC/FTD and GC/MS method were used to identify the target substance and quantify the acrylamide. The recoveries obtained from samples spiked with standards at the levels of 37.5μg/kg were in the range of 70.9%-87.6% and relative standard deviations (n=7) is 9.8%. Linearity of peak area was obtained over a wide range of concentration (0.05 to 5000g/L), and the correlation coefficient was greater than 0.999. The method is better than gas chromatography method and is reliable, selective and reproducible. It can be used in research of the acrylamide in fried instant noodle.
出处
《食品科学》
EI
CAS
CSCD
北大核心
2006年第9期229-232,共4页
Food Science
基金
河南省重大科技攻关计划项目(0422031200)
关键词
气相色谱-质谱联用
丙烯酰胺
油炸方便面
gas chromatography/mass spectrometry
acrylamide
fried instant noodle