摘要 本研究采用电絮凝技术预处理垃圾渗滤液,在以铁为阳极、不锈钢为阴极,极板距离1·5cm,电流密度50mA/cm2,不外加电解质的情况下,电解90min,渗滤液的CODCr去除率达到57·6%,NH4+去除率达40·1%,BOD5/CODCr比值由0·15提高到0·32,达到了较好的预处理效果。 A study of pretreatment of leachate by electro-coagulation method was carried out.Using Fe anode and stainless steel cathode,electrode spacing was 1.5 cm,current intensity was 50 mA/cm^2 and electrolytic time was 90 minutes without adding electrolyte.The removal rates of COD_ Cr and NH^+_4 reached 57.6% and 40.1% respectively,the BOD_5/COD_ Cr ratio was improved from 0.15 to 0.32.So this method reached a good pretreatment effect.
出处 《环境工程》 CAS CSCD 北大核心 2006年第5期29-30,37,共3页 Environmental Engineering
基金 国家自然科学基金项目(50478006)
关键词 渗滤液 预处理 电絮凝 可生化性 leachate,pretreat,eletro-coagulation and biochemical degradability
  • 相关文献

参考文献10

二级参考文献41

  • 1何晓莉,王志盈,袁林江.管式电凝聚法处理印染废水COD的特性研究[J].给水排水,2000,26(5):33-35. 被引量:17
  • 2邓皓,王蓉沙.电絮凝浮选法处理含油废水实验[J].江汉石油学院学报,1994,16(1):62-65. 被引量:5
  • 3姚珺.造纸废水的处理[J].洛阳大学学报,1994,9(2):45-53. 被引量:2
  • 4王三反,李桂荣,于连群,张淑英.高浊度水二级电凝聚处理工艺[J].给水排水,1996,22(3):11-14. 被引量:4
  • 5唐受印.废水处理工程[M].化学工业出版社,1999,1.247-258.
  • 6[1]Lema J M, Mendez R, Blazquez R. Characteristics of landfill leachate and alternatives for their treatment: a review[J]. Water Air and Soil Pollution, 1988, 40: 223~250.
  • 7[2]Swartz R C. Consensus sediment quality guidelines for PAHs mixtures[J]. Environ. Toxicol. and Chem., 1999, 18(4):780~787.
  • 8[3]Larry H K, William A T. Priority pollutants[J]. ES&T, 1979, 4(3): 416.
  • 9[5]Genders D J, Weinberg N. Electrochemistry for a cleaner environment. Electrosynthesis Company Inc, 1992, 6~14.
  • 10[6]Keith Csott. Electrochemical Process for Clean Technology[M]. Cambridge UK: Published by the Royal Society of Chemistry, 1995. 2~27.

共引文献121

同被引文献179

引证文献11

二级引证文献117

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部