摘要
以流速为1.0 mL/m in的2.4 mm o l.L-1N a2CO3+3.0 mm o l.L-1N aHCO3作为淋洗液,且采用YSA型8180A-4#分离柱和W IC-Ⅱ型电导检测器,研究了离子色谱法同时测定水中常见的三种阴离子NO2-、NO3-和PO43-.结果表明可以在16 m in内一次性检测出三种离子,三种离子的线性范围为0 m g.-L 1~8 m g.L-1,线性相关系数为r>0.999 0,变异系数为1.25%~1.71%,方法回收率为96.0%~101.0%.
A 2.4 mmol·L^-1Na2CO3+3.0 mmol·L^-1NaHCO3 solution with a flow rate 1. 0 ml/min was used, adopting YSA 8180A-4 # high separating column and WIC-Ⅱ electrochemical detector, ion chromatography for the simultaneous determination of three inorganic anions NO2^-,NO3^- and PO4^3- in the ambient samples was studied. The result indicated that three anions were detected in 16 minutes,the correlation coefficient rage was 0 mg·L^-1~8 mg·L^-1,the coefficients was more than 0. 999 0,the CV% was 1.25%~1.71%,the recoveries was 96.0%~101.0 %.
出处
《太原师范学院学报(自然科学版)》
2006年第3期101-103,共3页
Journal of Taiyuan Normal University:Natural Science Edition
关键词
离子色谱法
阴离子
测定
ion chromatography
inorganic anions
determination