期刊文献+

动态光谱法对提高近红外无创血液成份检测精度的理论分析 被引量:33

THEORETIC STUDY ON IMPROVING NONINVASIVE MEASUREMENT ACCURACY OF BLOOD COMPONENT BY DYNAMIC SPECTRUM METHOD
下载PDF
导出
摘要 近红外光谱无创血液成分检测因测量方法具有优越性,已经成为生物医学领域的研究热点之一.但除血氧以外,目前还没有进入临床应用的报道,其原因在于个体差异和测量条件对检测精度的影响.研究了一种不同于传统的新检测方法-动态光谱法可使测量精度提高.先从检测原理出发,研究了传统的近红外无创血液成分测量过程中产生误差、造成测量精度较低的因素;再分析了动态光谱法对这些因素的抑制或克服.从理论上得到了动态光谱法可以大大提高血液成分无创检测精度的结论,为基于光谱法的无创血液成分检测的临床应用提供了条件. Utilizing near-infrared spectroscopy for non-invasive blood component concentration sensing has been a focusing topic in biomedical optics applications. But, there is no report about any successful detection techniques that can satisfy the requirements of clinic application (except the blood oxygen). One of the most important difficulties is the effect of the individual discrepancy. Dynamic spectrum (DS) is a new detecting method for blood spectrum developed in recent years. The improvement of accuracy by DS was studied compared with the traditional way here. The errors of traditional NIR non-invasive blood component concentration decision were studied based on the measure theory. Then the way of eliminating these errors by DS was analysed. Our conclusion is that the DS method can improve the accuracy of non-invasive blood component concentration measuring.
出处 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2006年第5期345-348,共4页 Journal of Infrared and Millimeter Waves
基金 国家自然科学基金资助项目(60174032)
关键词 血糖浓度 无创检测 动态光谱 测量精度 blood component concentration noninvasive measurement dynamic spectrum detecting accuracy
  • 相关文献

参考文献8

  • 1黄岚,田丰华,丁海曙,王广志,腾铁超.用近红外光谱对组织氧测量方法的研究[J].红外与毫米波学报,2003,22(5):379-383. 被引量:35
  • 2骆清铭,邓晖,龚辉,曾绍群,陈卫国.用于脑血流量检测的近红外光谱术[J].红外与毫米波学报,1999,18(2):138-144. 被引量:15
  • 3Heise H M.Encyclopedia of analytical chemistry[M].Chichester:John Wiley.2000.
  • 4LI Gang,WANG Yan,LIN Ling,et al.Dynamic spectrum:a brand-new non-invasive blood component measure method[C].Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference Shanghai,China,September 1-4,2005.
  • 5WANG Yan,LI Gang,LIN Ling,et al.Study on the error in the dynamic spectrum method relative with the pathlength factor as a function of wavelength[C].Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference Shanghai,China,September 1-4,2005.
  • 6Kubo Hiroko,Mitsumura Yoshio,Uenoyama Harumi,et al.Method and apparatus for measureing concentration by light projection[P].U.S.Patent,6147749,Nov.14,2000.
  • 7Shangguan H,Prahl S L.Pressure effects on soft tissues monitored by changes in tissuer optical properties,in Laser-Tissue Interaction IX[C].S.L.Jacques Ed,Proc.SPIE 1998,3254:366-371.
  • 8LI Qing-Bo,WANG Yan,XU Ke-Xin.Determination of instrumental precision requirement for the expected glucose prediction accuracy[C].Proceedings of SPIE,2002

二级参考文献15

  • 1Masatsugu Niwayama, Lin L, Shao J, et al. Quantitative measurement of muscle oxygenation by NIRS: Analysis of the influence of subcutaneous fat layer and skin. SPIE, 1999,3597 : 291-299.
  • 2Masatsugu Niwayama, Takafumi Hamoka, Ling Lin, et al.Quantitative muscle oxygeantion measurement using NIRS with correction for influence of a fat layer: comparison of oxygen consumption rates with measurements by other technique. SPIE, 2000, 3911:256-265.
  • 3Jobsis F F. Noninvasive infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters.Science, 1977, 198(4323): 126d-1267.
  • 4COPE M, DEPLY D T. System tor long term measurement of cerebral blood and tissue oxygenation on infants by near infrared transillumination. Phys Med Biol , 1988, 33:1433-1442.
  • 5Wickramasinghe Y, Liver L N, Spencer S A, et al. Plethysmographic validation of near spectroscopy monitoring of cerebral blood volumm. Arch Dis Child , 1992, 76:407-411.
  • 6Shiga T, Tanabe K, Nakase Y, et al. Development of a portable tissue oximeter using near infrared spectroscopy.Medical & Biological Engineeriug & Computing, 1995, 33:622- 626.
  • 7Susumu Suzuki, Sumio Takasaki, Takeo Ozaki, et al. A tissue oxygenation monitor using NIR spatially resolved spectroscopy. SHE, 1999, 3597:582-592.
  • 8Lehr H-P, Wickramasinghe Y. New prototype NIRS to investigate multi-regional cerebral blood and tissue oxygenation and haemodynamics. Medical & Biological Engineering & Computing, 2000, 38:281-286.
  • 9Feng S, Zeng F. Monte Carlo simulation of photon migration path distributions in multiple scattering media. SPIE, 1993,1888 : 78-89.
  • 10Luo Q, Nioka S, Chancce B. Functional near-infrared imager. SPIE, 1997, 2979:84-93.

共引文献48

同被引文献328

引证文献33

二级引证文献144

相关作者

内容加载中请稍等...