摘要
分析了游泳池水面蒸发率的影响因素。应用常用的计算公式计算了某室内游泳馆的水面蒸发率,并进行了测试。比较了计算值与实测值,推荐了游泳池平静水面时和一般使用时水面蒸发率的计算公式。
Analyses the affecting factors on the rate of water evaporation from swimming pools. Compares the measuring results of the evaporation rate with those calculated from common formulas and recommends the formulas respectively for the off and operation periods.
出处
《暖通空调》
北大核心
2006年第9期68-71,共4页
Heating Ventilating & Air Conditioning
关键词
室内游泳馆
平静水面
水面蒸发量
人员密度
温差
natatorium, calm water surface, normal operation, water surface evaporation rate, occupancy, temperature difference