目的建立妇科调经片中阿魏酸的HPLC测定方法。方法C18柱(Shim-pack,6.0×150mm,5μm),甲醇-0.1%磷酸溶液(30:70)为流动相,检测波长320nm,流速:1mL·min^-1。结果此方法在浓度0.020~2.036μg范围内线性关系良好,平均加样回收率为100.0%,RSD为1.55%。结论本方法可用于妇科调经片中阿魏酸的含量监控。
OBJECTIVE To establish a method for the determination of ferulic acid in Fuke Tiaojing tablets. METHODS The C18 column was used in this method, and a mixture of methanol and 0.1% phosphoric acid solution (30 : 70) was used as a mobile phase, detection wavelength was 320nm. RESULTS This method showed a good linear relationship, the mean recovery was 100.0%. CONCLUSION This method can be used for the quality control of Fuke Tiaojing tablets.