期刊文献+

符合多标准的泄漏电流测试系统的软件实现 被引量:1

Research on the Test Technique of Leakage Current under Multi-Standard and Multi-System Based on Software
下载PDF
导出
摘要 介绍一种基于软件实现设计符合最新IEC、UL等多种标准的泄漏电流测试系统。首先系统地研究IEC和UL两大电气安全检测标准体系,对IEC、UL的最新标准中提出的测量泄漏电流过程中所采用的多种人体阻抗网络进行分析得出频率因数,在此基础上应用软件对测得值进行加权计算实现设计符合多标准的泄漏电流测试系统。该系统由单一模拟人体阻抗网络、信号处理电路、高速AD转换、计算机和能够实现多标准测试的软件等组成。实验表明,测试系统具有测试方法符合多种标准的测试要求,电路简单,测试精度高和测试过程自动化等特点。 The test technique and system of leakage current under multi-standard based on software is introduced in the paper. The two safety standard systems such as the standard of IEC(International Electro-technical Commission) and the standard of UL(Underwriters Laboratories Inc.) was introduced in detail. Four simulation body resistance networks developed in the standards of IEC and UL was analyzed to obtain frequency factor and a system corresponding to multi-standard and multi-system which based on software is designed. The system is composed of single simulation body resistance network, a signal processing circuit, a high-speed A/D converter, a computer and the software which under multi-standard and multi-system. The experiment result indicated that the test system possesses many characteristics, such as corresponding to multi-standard and multi-system, simply circuit, high accuracy and automation.
出处 《仪器仪表标准化与计量》 2006年第5期1-3,6,共4页 Instrument Standardization & Metrology
基金 科技部2005年科研院所专项项目 北京市重点实验室(机电系统测控)资助。
关键词 标准 泄漏电流 频率因数 测试 Standard Leakage Current Frequency Factor Test Technique
  • 相关文献

参考文献3

  • 1[1]International Standard IEC 61010-1 (2001-02),Safety Requirements for Electrical Equipment for Measurement,Control and Laboratory Use-Part 1:General Requirements.[S]
  • 2[2]International Standard IEC 60990-1 (1999-08),Methods of measurement of touch current and protective conductor current
  • 3付永川.泄漏电流及其测试[J].标准化报道,1999,20(3):40-41. 被引量:3

共引文献2

同被引文献4

引证文献1

二级引证文献3