摘要
通过对东莞电厂水冷壁爆管试样的宏观形貌、化学成分、金相、力学性能和微观区域分析,得出其发生爆管的主要原因是氢损伤。
Analyzes the macroshape, chemical composition, metallography, mechanical performance and microscopic area of the water wall tubes burst sample in Dongguan Power Plant, concludes hydrogen impairment caused the burst.
出处
《宁夏电力》
2006年第5期48-50,共3页
Ningxia Electric Power
关键词
水冷壁
爆管
氢损伤
the water wall, the tubes burst, hydrogen impairment