摘要
通过钢框架外挂足尺陶板幕墙模型的振动台试验,研究了陶板幕墙的抗震性能。试验分别输入El-Centro地震波、人工波及Taft记录波。试验结果表明,陶板幕墙系统具有良好的抗震性能,符合抗震设计要求。
In order to study and testify the seismic behavior of ceramic curtain wall, a steel frame model with full-scale ceramic curtain wall system was made and the shaking table test was done. El-Centro wave, man-made wave and Taft wave were selected to input respectively in the test. The results show that the inspected ceramic plate curtain wall system behaves quite well and the seismic design requirements are met.
出处
《建筑结构》
CSCD
北大核心
2006年第10期95-97,共3页
Building Structure
关键词
陶板幕墙
振动台试验
抗震性能
ceramic plate curtain wall
shaking table test
seismic behavior