摘要
详细介绍了变压器常发性故障—铁芯多点接地的几种类型及成因,从而提出变压器铁芯多点接地故障的分析处理程序并列举了两个处理实例进行说明.
This paper gives a particular description for the reasons about what is wrong with transformer' s iron - core connecting to earth in some points. It proposes a program about analyzing and settling the problem of transformer's iron-core connecting to earth in some points, and gives two examples to explain the program.
出处
《佳木斯大学学报(自然科学版)》
CAS
2006年第4期563-566,共4页
Journal of Jiamusi University:Natural Science Edition
关键词
变压器
铁芯
接地
故障
程序
transformer
iron-core
connect to earth
fault
program