期刊文献+

建立无人通信站空调自启动装置 被引量:1

Air-conditioner self-starting equipment in duty-free communication station
下载PDF
导出
摘要 为了解决无人值守通信站的室内空调在炎热夏季因拉闸限电停运过后,来电不能自动重启,给站内电子设备带来安全隐患的问题,文章研制了一个空调来电自启动装置,效果很好。围绕该装置的技术要求、工作原理设计,以及它对通信设备安全、环网正常运行所起的积极作用进行了论述。 The air-conditioner in duty-free communication station cannot self-start when power supply is turned on again after power supply is limited then cut off in the summer high temperature season, and the temperature in equipment room will rise and the equipment will face security problems, To solve this problem, an air-conditioner self-starting equipment is designed, and the effect is quite well. This paper discusses the technical requirement and working principle of this equipment. It also discusses positive function to communication equipment security and normal operation of ring network.
作者 杜庆
出处 《电力系统通信》 2006年第11期72-74,共3页 Telecommunications for Electric Power System
关键词 空调 自启动 自动控制 air conditioner self-starting automatic control