期刊文献+

低剂量MSCT尿路造影对非扩张性输尿管的显示与测量 被引量:7

The Display and Measurement for Non-dilated Ureter with Low-dose Multi-slice CT Urography
下载PDF
导出
摘要 目的:探讨多层螺旋CT尿路造影对非扩张性输尿管图像质量的影响,并测量输尿管管径大小正常值范围。方法:根据螺旋CT扫描时管电流的设置,将38例行MSCTU患者中的72侧非扩张性输尿管分为常规剂量组和低剂量组,分别测量辐射剂量值;采用评分法观察图像质量,并进行统计学检验;在MSCTU条件下,测量输尿管正常管径的大小。结果:在其它扫描参数为默认设置的条件下,将管电流由常规mA(180—250mA)降至低mA(50,120mA)时,患者所接受的平均辐射剂量由15.19mGy降至5.66mGy(P〈0.05),而MSCTU图像质量无明显下降(P〉0.05)。在MSCTU条件下正常输尿管平均管径大小为5.23mm,95百分位数值为6.93mm。结论:单纯降低管电流,能在保证图像质量的前提下,有效降低辐射剂量。MSCTU状态下正常输尿管管径的上限值为7mm。 Objective: To determine the display effect of non- dilated ureter with reducing mA on the image quality in patients undergoing multi - slice CT urography, and to measure the normal ureter size. Methods: Seventy - two sides of non - dilated ureters in thirty - eight patients were divided into routine - dose and low- dose groups according to the fixed kv set. The radiation dose was measured and image quality was evaluated by twelve - points method. Measure the normal size of ureter with MSCTU. Results: Mean radiation dose to the patients was significantly reduced from 15.19mGy ( 180 - 250mA) to 5.66 mGy (50 - 120mA) ( P 〈 0.05). No significant difference of the image quality was found between the two groups ( P 〉 0.05). The mean normal size of ureter is 5.23mm on MSCTU. On 95% patients, the normal ureter diameter is 6,93mm or smaller; Conclusion: MSCTU scanning of the ureters can be performed at greatly reduced lose without loss the image quality. The upper limit of normal ureter size on MSCTU is 7mm.
作者 熊燕 邓开鸿
出处 《华西医学》 CAS 2006年第4期736-737,共2页 West China Medical Journal
关键词 低剂量 体层摄影术 X线计算机 尿路造影 输尿管 low - dose Tomography X - ray computed urography ureter size
  • 相关文献

参考文献8

  • 1Kalra MK,Maher MM,Sahani DV,et al.Low-dose CT of the abdomen:evaluation of image improvement with use of noise reduction filters-pilot study[J].Radiology,2003,228(7):251-256.
  • 2周阳泱,韩萍,冯敢生,陈祖云,杨想军,李友林,雷子乔,R.Sokiranski.鼻窦低剂量CT扫描对图像质量影响的研究[J].中华放射学杂志,2005,39(3):239-243. 被引量:68
  • 3张骥,吴伟君,蒋海燕.儿童颅脑外伤CT扫描参数的优化设置[J].放射学实践,2005,20(10):893-896. 被引量:5
  • 4Catalano O,Nunziata A,Altei F,et al.Suspected urereral colic:primary helical CT versus selective helical CT after unenhanced radiography and sonography[J].AJR,2002,178(2):379-383.
  • 5Kocakoc E,Bhatt S,Dogra VS.Renal multidector row CT[J].Radiol Clin North Am,2005,43(11):1021-1047.
  • 6Spielmann AL,Heneghan JP,Lee LJ,et al.Decreasing the radiation dose for renal stone CT:a feasibility study of single-and multidetector CT[J].AJR,2002,178(5):1058-1062.
  • 7Kenney PJ.CT evaluation of urinary lithiasis[J].Radiol Clin North Am,2003,41(5):979-999.
  • 8Zelenko N,Coll D,Rosenfeld AT,et al.Normal ureter size on unenhanced helical CT[J].AJR,2004,182(4):1039-1041.

二级参考文献15

  • 1Hein E, Rogalla P, Klingebiel R, et al. Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose. Eur Radiol, 2002, 12:1693-1696.
  • 2Czechowski J, Janeczek J, Kelly G, et al. Radiation dose to the lens in sequential and spiral CT of the facial bones and sinuses. Eur Radiol, 2001, 11:711-713.
  • 3Kennedy DW, Zinreich SJ, Rosenbaum AE, et al. Functional endoscopic sinus surgery: theory and diagnostic evaluation. Arch Otolaryngol, 1985, 111:576-582.
  • 4Han P, Pirsig W, Ilgen F, et al. Virtual endoscopy of the nasal cavity in comparison with fiberoptic endoscopy. Eur Arch Otorhinolaryngol, 2000, 257:578-583.
  • 5Klevansky A. The efficacy of multiplanar reconstructions of helical CT of the paranasal siunses. AJR, 1999, 173: 493-495.
  • 6Hilger AW, Ingels K, Joosten F. Sagittal computerized tomography reconstruction of the lateral nasal functional endoscopic sinus surgery. Clin Otolaryngol, 1999, 24: 527-530.
  • 7Meloni F, Stomeo F, Bozzo C, et al. Computerised tomography evaluation of the frontal recess in inflammation diseases of the frontal sinus: standardisation of a new technique. Rhinology, 1997, 35: 28-32.
  • 8Brenner DJ,Elliston CD, Hall EJ. Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT[J]. AJR, 2001,176 (2):289-295.
  • 9Slovis TL. ALARA Conference Proceedings. The ALARA Concept in Pediatric CT-Intelligent dose Reduction [J]. Pediatric Radiol, 2002,32 (10): 4.
  • 10Huda Walter. Dose and Image Quality in CT[J]. Pediatric Radiol,2002,32(10) :709-713.

共引文献71

同被引文献32

  • 1李美花,范利.老年人造影剂肾病及临床相关因素分析[J].中国老年学杂志,2005,25(6):649-651. 被引量:23
  • 2王玲,倪兆慧,何奔.对比剂肾病研究进展[J].介入放射学杂志,2007,16(1):66-69. 被引量:12
  • 3Nakada SY,Hoff DG,Attai S,et al.Determination of stone composition by non contrast spiral computed tomography in technical setting[J].Urology,2000,55(4):816-819.
  • 4Tilo N,Thilo K,Georg B.Diagnostic Performance of Low-Dose CT for the Detection of Urolithiasis:A Meta-Analysis[J].Am J Roentgenol,2008,191(8):396-401.
  • 5Pfister SA,Deckart A,Laschke S,et al.Unenhanced helical computed tomography vs intravenous urography in patients with acute flank pain:accuracy and economic impact in a randomized prospective trial[J].Eur Radiol,2003,13(11):2513-2520.
  • 6Bongartz G, Golding SJ, Jurik AG, et al. Report EUR 1626zen Luxembourg:office for official publications of the European con, munities, 1999 : 70.
  • 7Niemann T, Kollmann T, Bongartz G. Diagnostic performance of low-dose CT for the detection of urolithiasis: a meta analysis[J]. Am J Roentgenol, 2008,191 (8) : 396- 401.
  • 8Chevreau G, Troccaz J, Conort P, et al. Estimation of urinary stone composition by automated processing of CT images[J]. Urol Res, 2009,37(5):241 245.
  • 9Kalra MK, Msher MM, Toch TL, et al. Strategies for CT radiation dose optimization[J]. Radiology, 2004,230(3) : 619 -628.
  • 10Nolte-Ernsting CC,Bücker A,Adam GB,et al.Gadolinium-enhanced excretory MR urography after low-dose diuretic injection:comparison with conventional excretory urography[J].Radiology,1998,209(1):147-157.

引证文献7

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部