灌注成像与CT发展在脑肿瘤中的应用
Progress of perfusion imaging and CTperfusion imaging and their application in encephalon tumors
摘要
CT灌注成像技术中各种灌注参数本质上反映了脑肿瘤的血流动力学特点与肿瘤内部微血管密度的情况,不同组织学类型的脑肿瘤,其病理生理及血流动力学改变也不尽相同。研究不同性质不同级别脑肿瘤的绝对灌注参数之间的差异及与肿瘤的相关性,对脑肿瘤的定性诊断与鉴别诊断有重要意义。本文重点介绍灌注成像的发展、各种灌注成像技术在脑部应用的比较与CT灌注成像优势。
出处
《实用医院临床杂志》
2006年第6期76-78,共3页
Practical Journal of Clinical Medicine
参考文献24
-
1[1]Miles KA,Hagball MP,Dixon AK.Measurement of human pancreatic perfusion using dynamic computed tomography with perfusion imaging[J].Br J Radiol,1995,68(80):471.
-
2[2]Terada T,Nambu K,Hyotani G,et al.Cerebral blood flow a method for quantitative measurement of cerebral vascular permeability using X-ray CT and iodinated contrast X-ray CT and iodinated contrast X-ray CT and iodinated contrast.medium[J].Neuroradiology,1992,34:290-296.
-
3[3]Miles KA,Griffiths MR.Perfusion CT:a worthw-hile enhancement[J].Br J Radiol,2003,76(904):220-231.
-
4[4]Cenic A,Nabavi DG,Craen R A,et al.A CT method to measure homodynamic in brain tumors:validation ad application of cerebral blood flow maps[J].AJNR,2000,21 (3):4622-4700.
-
5[5]CenicA,Nabavi DG,Graen RA,et al.Dynamic CT measurement of cerebral blood flow-Avalidation study[J].AJNR,1999,20 (1):632-633.
-
6[6]Lee TY,Nabavi DG,Graen RA,et al Validation of ce-rebral blood flow map from contrast enhanced cine CT scanning:Comparison of infarct sizes from TTC staining and blood flow threshold in a rabbit focal cerebral ischemia model[J].Radiology,2000,213 (S):1305.
-
7[7]Cenic A,Nabavi DG,Craen RA,et al.A CT method to measure he-modynamic sin brain tumors:Validation and application of cerebral blood flow maps[J].AJNR,2000,21 (3):462-470.
-
8[8]Delorme S,Knopp MV.Non-invasive vascular ima-Ging:assessing tumor vascularity[J].Eur Radiol,1998,8(4):517-527.
-
9[9]Meier P,Zierler KL.On the theory of the indicator-dilution method for measurement of blood flow and volume[J].J Appl Physiol,1954,6(12):731-744.
-
10[10]Shin JH,Lee HK,Kwun BD,et al.Using relative cerebral blood flow and volume to evaluate the his-topathologic of cerebral gliomas:prelimibary results[J].AJNR,2002,179 (3):783-789.
二级参考文献39
-
1Klotz E, Konig M, Perfusion measurements of the brain: Using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke. Eur J Radiol, 1999, 30(3): 170
-
2Koenig M, Klotz E, Luka B, et al. Perfusion CT of the brain: Diagnostic approach for early detection of ischemic stroke. Radiology, 1998, 209(1): 85
-
3Mayer TE, Hamann CF, Baranezyk J, et al. Dynamic CT perfusion imaging of acute stroke. AJNR, 2000, 21(8): 1441
-
4Ladurner G, Zilkha E, Iliff D, et al.Measurement of regional cerebral blood volume by computerized axial tomography. J Neurol Neurosurg Psychiatry, 1976, 39(2): 152
-
5Traupe H, Heiss WD, Hoeffken W, et al. Hyper perfusion and enhancement in dynamic computed tomography of ischemic stroke patients. J Compant Assist Tomogr, 1979, 3(5): 627
-
6Axel L. Cerebral blood flow determination by rapid-sequence computed tomography. Radiology, 1980, 136(3): 679
-
7Miles KA. Measurement of tissue perfusion by dynamic computed tomography. Br J Radiol, 1991, 64(761): 409
-
8Miles KA, Hagball MP, Dixon AK. Functional imaging of hepatic perfusion obtained with dynamic CT. Radiology, 1993, 188(2): 405
-
9Miles KA, Hagball MP, Dixon AK. Measurement of human pancreatic perfusion using dynamic computed tomography with perfusion imaging. Br J Radiol, 1995, 68(80): 471
-
10Terada T, Nambu K, Hyotani G, et al. Amethod for quantitative measurement of cerebral vascular permeability using X-ray CT and iodinated contrast medium. Neuroradiology, 1992, 34(4): 290
共引文献16
-
1施裕新,徐建峰.CT灌注成像对脑肿瘤瘤周水肿的评价[J].中华放射学杂志,2005,39(5):469-471. 被引量:18
-
2夏爽,祁吉.颅内肿瘤术前CT灌注检查[J].诊断学理论与实践,2005,4(4):330-332. 被引量:1
-
3徐剑峰,施裕新.CT 灌注成像在脑膜瘤与脑转移瘤鉴别诊断中的价值[J].中国临床医学,2005,12(5):908-910. 被引量:2
-
4胡春洪,吴庆德,王雪元,诸伟,沈海林,傅引弟,丁乙.常用对比剂流率下脑CT灌注量计算方法的改良[J].中华放射学杂志,2007,41(1):22-25.
-
5石士奎,程敬亮.CT灌注成像在颅脑肿瘤诊断中的应用及其展望[J].实用放射学杂志,2007,23(9):1270-1273. 被引量:1
-
6曾祥柱,李选,高文清,余若晖,刘晨.MSCTP成像结合CTA评价兔慢性骨骼肌缺血侧支动脉生成和灌注恢复[J].中国医学影像技术,2009,25(8):1339-1342. 被引量:3
-
7马宜传,付凯,陈岩,丁强,孙景秋.星形细胞瘤脑血容量与RhoA表达相关性研究[J].蚌埠医学院学报,2009,34(8):721-723.
-
8吴刚,余永强,钱银锋,王万勤.64层螺旋CT灌注成像在脑星形细胞瘤分级诊断中的价值[J].安徽医学,2010,31(7):806-809. 被引量:3
-
9尚瑶,李选.CT灌注成像在外周动脉梗阻性疾病中的应用[J].中国介入影像与治疗学,2010,7(5):567-570. 被引量:3
-
10徐鹏,张骅.CT灌注成像的临床应用进展[J].疑难病杂志,2010,9(10):794-796. 被引量:3
-
1杨扬,李功杰.乳腺肿瘤CT灌注成像及其临床应用研究进展[J].军事医学科学院院刊,2007,31(3):290-293. 被引量:1
-
2钟朝晖,卢东生.多层螺旋CT的技术特点和临床使用及发展趋势[J].中国医学影像技术,2002,18(11):1189-1191. 被引量:3
-
3张海涛,舒圣捷,刘白鹭.孤立性肺结节CT灌注成像技术研究现状与进展[J].医学影像学杂志,2011,21(12):1909-1913. 被引量:7
-
4梅海英,周星辉,付福亮,徐建潮.多层螺旋CT灌注成像在鼻咽癌的临床应用[J].实用放射学杂志,2009,25(6):911-913. 被引量:1
-
5杨本强,周丽娟,关长群.质子磁共振波谱与灌注成像技术在评价脑胶质瘤中的临床应用[J].沈阳部队医药,2007,20(3):191-193.
-
6吕秀英,颜雨春,刘斌,王万勤.多排螺旋CT灌注成像在涎腺肿块鉴别诊断中的应用[J].安徽医科大学学报,2010,45(2):231-234. 被引量:2
-
7马娅琼,徐香玖,黄刚,毛泽庆,左晓娜,王亚群.多层螺旋CT灌注成像技术在诊断肾肿瘤中的临床应用[J].实用放射学杂志,2011,27(5):743-746. 被引量:9
-
8余立新.延长CT球管使用寿命的方法探讨[J].实用医学影像杂志,2013,14(4):293-294. 被引量:1
-
9林顺发,周修国.多层螺旋CT技术原理及临床应用[J].实用医学杂志,2004,20(9):1079-1080. 被引量:1
-
10张平寅,钱英.对多层CT技术指标和软件的探讨与研究[J].医疗设备信息,2001,16(12):34-36. 被引量:1