摘要 目的研究Philips Brilliance64ECG编辑软件在冠状动脉CTA检查中的临床应用价值及其影响因素。方法收集28例经ECG编辑软件处理前后的冠状动脉CTA影像进行分析,对直径≥2mm的冠状动脉数据带进行评估。影像质量按3级评分法判定,运用配对样本t检验及Spearman秩相关检验进行统计学处理。结果28例中,心律失常22例,扫描时心电图基线不稳6例。共有38个数据带出现运动伪影,36个为Ⅲ级严重伪影,2个为Ⅱ级。经ECG编辑处理后,心电编辑后1个数据带为Ⅲ级;9个数据带为Ⅱ级;28个数据带为Ⅰ级无任何伪影。配对样本t检验P<0.001;Spearman秩相关检验显示心电编辑后影像的质量与患者扫描时心率呈负相关,r=-0.485(P=0.009)。结论ECG编辑软件可以明显地减轻或消除心律失常或心电图异常导致的冠状动脉CTA伪影,提高影像的质量及检查的成功率。 Objective To evaluate the ECG-edit software of Philips Brilliance 64 CT in CT coronary angiography and its influencing factors. Methods Among the patients with CT coronary angiography in the past 8 months, 28 patients were included in this study as their images were processed with ECG-edit software. The image quality of data bands affected by abnormal ECG was analyzed, and classified into three grades. The paired-sample t test and spearman test of correlation coefficients were used to statistical analysis. Results There were 22 patients having arrhythmia, and 6 having ECG baseline abnormality. The image quality was affected in 38 data bands of 28 patients. Before processed with ECG-edit software, 36 data bands of image had severe artifact (grade Ⅲ ), 2 had mild (grade Ⅱ ). After processed, 28 data bands had no artifact (grade Ⅰ), 9 had mild, and one had severe artifact. There was significant difference between image quality of before and after ECG- edit processed (P〈0. 001). The spearman test revealed that the images quality after ECG-edit software processed was negatively correlated with the patients' heart rate (P=0. 009). Conclusion ECG-edit software can reduce or obliterate the artifact that was induced by arrhythmia or ECG baseline abnormality, and improve the image quality.
出处 《中国医学影像技术》 CSCD 北大核心 2006年第10期1485-1488,共4页 Chinese Journal of Medical Imaging Technology
关键词 体层摄影术 X线计算机 冠状动脉疾病 心率 Tomography, X-ray computed Coronary artery disease Heart rate
  • 相关文献

参考文献10

  • 1American Heart Association.Heart disease and stroke statistical-2005 update[R].Dallas,Tex:American Heart Association,2005.
  • 2龚艳君,霍勇.64排CT冠状动脉成像的临床应用现况[J].中国介入心脏病学杂志,2005,13(6):416-416. 被引量:26
  • 3Flohr T,Schoepf UJ,Kuettner A,et al.Advances in cardiac imaging with 16-section CT systems[J].Acad Radiol,2003,10(4):386-401.
  • 4Adey H,Ballantyne DA,Bostock MI,et al.The prevalence of disturbance of cardiac rhythm in healthy New Zealand adults:a pilot study[J].N Z Med J,1978,88(625):433-435.
  • 5Clarke JM,Hamer J,Shelton JR,et al.The rhythm of the normal human heart[J].Lancet,1976,1(7984):508-512.
  • 6金征宇,张竹花,林松柏,李冬晶,陆菁菁,有慧,王云,王林辉,赵文敏,牟文斌,张立仁,朱文玲,张抒扬,倪超,贾宁,任华,于洪泉,苗齐,方圻.十六层螺旋CT冠状动脉造影的初步探讨[J].中华医学杂志,2003,83(13):1150-1155. 被引量:30
  • 7Nieman K,Rensing B,van Geuns R,et al.Non-invasive coronary angiography with multislice spiral computed tomography:impact of heart rate[J].Heart,2002,88(5):470-474.
  • 8Hoffmann MH,Shi H,Manzke R,et al.Noninvasive coronary angiography with 16-detector row CT:effect of heart rate[J].Radiology,2005,234(1):86-97.
  • 9姜荣,吴晓华,贺文.心率波动对多层螺旋CT冠脉造影图像质量的影响[J].中国医学影像技术,2004,20(10):1574-1576. 被引量:49
  • 10Nakanishi T,Kayashima Y,Inoue R,et al.Pitfalls in 16-detector row CT of the coronary arteries[J].Radiographics,2005,25(2):425-440.

二级参考文献12

  • 1Rumberger JA,Brundage BH,Rader DJ,et al.Electron beam computed tomographic coronary calcium scanning: a review and guidelines for use in asymptomatic persons. Mayo Clin Proc,1999,74:243-252.
  • 2Vogl TJ,Abolmaali ND,Diebold T,et al.Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography.Radiology, 2002,223:212-220.
  • 3Achenbach S,Giesler T, Ropers D,et al.Detection of coronary artery stenoses by contrast-enhanced,retrospectively electrocardio-graphically-gated,multislice spiral computed tomography.Circulation, 2001,103:2535-2538.
  • 4Schroeder S,Kopp AF,Baumbach A,et al.Noninvasive detection of coronary lesions by multislice computed tomography: results of the new age pilot trial. Cathet Cardiovasc Intervent,2001,53:352-358.
  • 5Achenbach S,Ulzheimer S,Baum U,et al. Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.Circulation,2000,102:2823-2828.
  • 6Nieman K,Rensing BJ,van Geuns RJ,et al.Usefulness of multislice computed tomography for detecting obstructive coronary artery disease.Am J Cardiol,2002,89:913-918.
  • 7Schroeder S,Kopp AF,Ohnesorge B,et al.Virtual coronary angioscopy using multislice computed tomography.Heart,2002,87:205-209.
  • 8Schroeder S,Kopp AF,Baumbach A,et al.Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography.J Am Coll Cardiol,2001,37:1430-1435.
  • 9Becker CR,Knez A,Ohnesorge B,et al. Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating.AJR Am J Roentgenol,2000, 175:423-424.
  • 10萧毅,田建明,王培军,秦永文,薛宏,李晓兵,王敏杰,左长京,曾浩,崔恒武.多层螺旋CT冠状动脉造影的扫描技术及临床应用[J].中华放射学杂志,2002,36(4):357-361. 被引量:144

共引文献102

同被引文献101

引证文献21

二级引证文献138

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部