摘要
介绍了一种以溶液为媒介的全热回收装置和制冷系统相结合的新风空调机———湿能空调机,它主要由送风模块,除湿模块,温度调节模块,再生模块等部分组成;简要阐述了其结构与工作原理,详细介绍了其测控系统,包括含有高精度仪表和传感器的硬件系统和有采集等功能齐全的软件系统,进行了性能试验测试,并对试验结果进行了分析总结,提出了一些改进的方法;经半年的测试运行,系统稳定可靠.
A new type of green air conditioner with liquid desiccant total heat recovery combined refrigeration system is introduced. It mainly constitutes of air delivery module, dehumidification module, temperature--adjusting module and regenerator module. Its configuration and operating principles are introduced simply. Testing system is described in detail. It contains hardware system with precision instruments and transducers and software system with multifunction. After performance experiment testing, the result is analyzed and summarized, some methods are provided to improve the performance too. By running testing for half a year, testing system is steady and reliable.
出处
《计算机测量与控制》
CSCD
2006年第10期1290-1292,1301,共4页
Computer Measurement &Control
关键词
溶液媒介
全热回收
新风
测控系统
liquid desiccant; total heat recovery; fresh air
testing system