摘要
分析了沙角A电厂4号、5号机组380V保安系统的运行情况,针对该保安系统在多次事故中未能起到应急备用的作用,提出了改造方案,对改造后的保安系统的事故处理方法、电压恢复等进行了分析,并总结运行经验,对保安系统的运行和维护提出建议。
This paper analyzes the operation of the 380 V emergency system for Units 4 & 5 in Shajiao A Power Station. A reconstruction plan is presented in view of the failures of the emergency system in multiple accidents, The emergency handling method and voltage recovery, etc. of the reconstructed system are analyzed. The operation experience is summarized, and suggestions on the operation and maintenance of the emergency system are offered as well.
出处
《广东电力》
2006年第10期42-45,共4页
Guangdong Electric Power
关键词
发电厂
厂用电设备
保安电源
电压消失
改造
power plants station service equipments emergency powers loss of voltages reconstruction