期刊文献+

一种新的光学相干层析成像中色散现象的补偿方法 被引量:1

A new method to compensate dispersion in optical coherence tomography
下载PDF
导出
摘要 光学相干层析成像技术中,样品的色散特性将降低获取图像的分辨力。通过实验获取了不同色散特性的样品的相干图像。实验采用中心波长为845nm,频谱宽度为26nm的超辐射光源。实验的样品为一块30mm厚的BK 7玻璃。根据光源的频谱信息和样品的色散系数,理论计算了OCT信号的包络,并与实验中测得的信号相对比。同时提出了一种新的数值方法,来补偿样品的色散。该方法可在时域或者频域OCT中方便地应用。通过实验验证了该方法的可行性。 It is known that dispersion in a sample degrades the resolution of signals in optical coherence tomography (OCT). In the paper, we investigate the OCT signals for some samples with different dispersions. A super-luminescent diode source with the center wavelength of 845nm and spectral width of 26nm was used. A 30mm thick BK7 glass slab was tested. Based on the measured source spectrum, the broadened signals are calculated with the specific dispersion coefficients. The calculated signals are compared with the results measured in the experiments. A general numerical dispersion compensation method is introduced, which can be applied both in time and frequency domains. The present method is verified experimentally.
出处 《光学仪器》 2006年第5期22-26,共5页 Optical Instruments
基金 国家自然科学基金资助项目(60372032)
关键词 光学相干层析成像 色散补偿 干涉图样 信号展宽 OCT dispersion compensation interferogram broadened signals
  • 相关文献

参考文献11

  • 1Huang D,et al..Optical coherence tomography[J].Science,1991,254(5035):1178~1181.
  • 2Schmitt J M.Optical coherence tomography (OCT):a review[J].IEEE Journal of Selected Topics in Quantum Electronics,1999,5(4):1205~1215.
  • 3Drexler W.Ultrahigh resolution optical coherence tomography[J].J Biomed Opt,2004,9(1):47~74.
  • 4Fujimoto J G.Optical coherence tomography for ultrahigh resolution in vivo imaging[J].Nat Biotechnol,2003,21(11):1361~1367.
  • 5Hitzenberger C K,Baumgartner A,Fercher A F.Dispersion induced multiple signal peak splitting in partial coherence interferometry[J].Opt Commun,1998,154(4):179~185.
  • 6Drexler W,Morgner U,Ghanta R K,et al..Ultrahigh resolution ophthalmic optical coherence tomography[J].Nature Medicine,2001,7(4):502~507.
  • 7Bouma B,Tearney G J,Boppart S A,et al..High-resolution optical coherence tomographic imaging using a mode-locked Ti-Al2O3 laser source[J].Opt Lett,1995,20(13):1486~1488.
  • 8Hitzenberger C K,Baumgartner A,Drexler W,et al..Dispersion effects in partial coherence interferometry:implications for intraocular ranging[J].J Biomed Opt,1999,4(1):144~151.
  • 9Golubovic B,Bouma B E,Tearney G J,et al..Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser[J].Opt Lett,1997,22(22):1704~1706.
  • 10Fercher A F,Hitzenberger C K,Sticker M,et al..Numerical dispersion compensation for partial coherence interferometry and optical coherence tomography[J].Opt Express,2001,9(12):610~615.

同被引文献12

  • 1俞晓峰,丁志华,陈宇恒,黄丽娜,周琳,周振明,吴兰,刘旭.光纤型光学相干层析成像系统的研制[J].光学学报,2006,26(2):235-238. 被引量:34
  • 2HUANG D,SWANSON E A,Lin C P,et al.Optical coherence tomography[J].Science,1991,254(5035),1178-1181.
  • 3TEARNEY G J,BREZINSKI M E,BOUMA B E,et al.In vivo endoscope optical biopsy with optical coherence tomography[J].Science,1997,276(5321),2037-2039.
  • 4SCHMITT J M.Optical coherence tomography (OCT):a review[J].IEEE J Select Topics Quantum Electron,1999,5 (4):1205-1215.
  • 5NISHIZAWA N,CHEN Y,HSIUNG P,et al.Real-time ultrahigh-resolution optical coherence tomography with an allfiber,femtosecond fiber laser continuum at 1.5μm[J].Opt Lett,2004,29(24):2846-2848.
  • 6HITZENBERGER C K,BAUMGARTNER A,FERCHER A F.Dispersion induced multiple signal peak unsplitting in partial coherence interferometry[J].Opt Oman,1998,154(4):179-185.
  • 7ASAKA K,OHBAYASHI K.Dispersion matching of sample and reference arms in optical frequency domain reflectometryoptical coherence tomography using a dispersion-shifted fiber[J].Opt Express,2007,15(8).5030-5042.
  • 8SMITH E D J,ZVYAGIN A V,SAMPSON D D.Real-time dispersion compensation in scanning interferometry[J].Opt Lett,2002,27(22):1998-2000.
  • 9BOUMA B E,TEARNEY G J.Handbook of optical coherence tomography[M].New York:Dekker Press,2002:42-44.
  • 10HARVEY A H,Gallagher J S,Levelt Sengers J M H.Revised formulation for the refractive index of water and steam as a function of wavelength,temperature and density[J].Phys Chem Ref Data,1998,27(4):761-774.

引证文献1