摘要
研究了在酸性介质下,氟化钠为掩蔽剂,用高碘酸钠来氧化对氨基苯磺酸,用催化动力学测定痕量锰的新方法,该方法检出下限为4×10-8g/mL,线性范围为0.05~0.6μg/mL,可应用于铝板中锰含量的测定。
A new method to measure trace manganese by catalytic dynamics,through the oxidation of sulfanilic acid by sodium iodate and taking sodium-fluoride for a masking agent in acid materials,is studied,The method whle lower limit of measure is 4×10-8g/mL and linear range 0.05 ̄0.6μg/mL,can be used for the measurement of manganese content in aluminum plates.
出处
《上海航天》
1996年第4期60-63,共4页
Aerospace Shanghai
关键词
催化动力学
光度法
锰含量
铝板
hotometry of catalytic dynamics, ̄+Sulfanilic acid,Manganese