摘要
我们观察到了石英375℃热释光峰存在灵敏度的变化。把石英作为剂量计来使用时,应当对375℃热释光峰作适当校正,以保证辐射源强度标定的准确性。
The response of 375℃ thermoluminescence (TL) peak of quartz to radiation can be changed. It is varied with the radiation dose accepted from the environment by the crystal. Therefore, it must be calibrated in any experiment for quartz's TL either as dosimeter or as TL dating. There are some data to explain this phenomenon in the present paper.
出处
《核技术》
CAS
CSCD
北大核心
2006年第11期826-829,共4页
Nuclear Techniques
基金
北京市自然科学基金(8002006)
北京市教委(KM200410028010)资助
关键词
热释光峰
电子陷阱
灵敏度
Thermoluminescence peak, Electron trap, Sensitivity