期刊文献+

辐射剂量计——石英375℃的热释光(TL)峰 被引量:3

The 375℃ thermoluminescence(TL) peak of quartz
下载PDF
导出
摘要 我们观察到了石英375℃热释光峰存在灵敏度的变化。把石英作为剂量计来使用时,应当对375℃热释光峰作适当校正,以保证辐射源强度标定的准确性。 The response of 375℃ thermoluminescence (TL) peak of quartz to radiation can be changed. It is varied with the radiation dose accepted from the environment by the crystal. Therefore, it must be calibrated in any experiment for quartz's TL either as dosimeter or as TL dating. There are some data to explain this phenomenon in the present paper.
出处 《核技术》 CAS CSCD 北大核心 2006年第11期826-829,共4页 Nuclear Techniques
基金 北京市自然科学基金(8002006) 北京市教委(KM200410028010)资助
关键词 热释光峰 电子陷阱 灵敏度 Thermoluminescence peak, Electron trap, Sensitivity
  • 相关文献

参考文献3

  • 1李虎侯.利用石英的热释光测定年代的技术[J].科学通报,1981,17:1068-1071.
  • 2Aitken M J.Thermoluminescence dating,Research Laboratory for Archaeolpgy and the History of Art,Oxford University,England,1985.20
  • 3Stuart F.Thermoluminescence technique in archaeology,Clarendon Press,Oxford,UK 1979,49

共引文献3

同被引文献25

引证文献3

二级引证文献3

相关作者