提出了开放式大面积办公场所的概念,针对大面积办公场所提出了对建筑物耐火等级、安全出口及疏散走道、防火门、内部装修、排烟系统及事故照明的要求。
Putting forward the idea of large open office place. Aimed at large open office place,the articl puts forward some claims for building grades of fire resistance ,evacuation exit and evacuation walk, fire door, interior decoration, smoke extraction system and emergency lighting.
出处
《消防科学与技术》
CAS
2006年第6期779-780,共2页
Fire Science and Technology
关键词
大空间建筑
疏散走道
防火门
large space building
evacuation walk
fire door