目的建立作业场所空气中锡的微波消解-原子荧光光度测定法。方法将采样完毕的微孔滤膜按微波消解程序处理后,将消解液进一步处理,以原子荧光光度法测定锡。结果方法的线性范围为0.3~100.0μg/L,检出限为0.3μg/L,最低检出浓度为0.0001mg/m3(以采集75L空气样品计),测定相对标准偏差为2.7%~3.5%,样品加标回收率为96.5%~104.7%。结论该方法具有快速准确、灵敏度高、精密度好等优点,可用于作业场所空气中锡的测定。
Objective To develop a method for determination of tin in the air of workplace by microwave digestion-HG-AFS. Methods The air samples were collected and the concentration of tin was determined by microwave digestion-HG-AFS and the parameters of atomic fluorescence spectrometry were studied. Results In the optimum condition, the detection limit of tin was 0.3μg/L, the lowest detected concentration of tin in the samples was 0.000 1 mg/m^3 (based on 75 L air sample), the RSD was 2.7%- 3.5%, the rate of recovery was in the range of 96.5%-104.7%. Conclusion The method is rapid, convenient, accurate, sensitive and suitable for determination of tin in the air of workplace.
出处
《环境与健康杂志》
CAS
CSCD
北大核心
2006年第6期555-556,共2页
Journal of Environment and Health
基金
上海市嘉定区科委科研基金资助项目(2004JKK023)
上海市嘉定区卫生局科研基金资助项目(KYXM-2004-11-3)
关键词
分光光度法
空气污染
锡
原子荧光光度法
微波消解
Spectrophotometry
Air pollution
Tin
Atomic fluorescence spectrometry
Microwave digestion