针对ASME流量喷嘴的试验标定,详细阐述了ASME PTC6-1996标准中关于试验标定的要求,并对国内流量喷嘴标定及校验数据处理中存在的问题进行了分析和阐述。对不满足标准要求的喷嘴的使用,提出了一种处理方法。最后,给出了应用实例。
Detailed requirements for the calibration of flow nozzles in ASME PTC6-1996 was described. Analysis was made for the problems in domestic flow nozzle calibration and processing of calibrated data. A method was suggested for the application of flow nozzles, which was non-conformed with the Code. Finally, an example was provided for the calibration process.