通过对同一空调风系统的不同区域采用末端变流量、电辅热微调等多种控制方法使小面积有精密空调要求的房间达到恒温恒湿目的。
The paper introduced how to make the small room that has accurate air-conditioning requirement to reach the goal of constant temperature and constant humidity by using multiple control methods such as changing flowrate at the end and finely adjusting with electric heating in different zones of the air system controlled by a same air conditioner.
出处
《有色冶金设计与研究》
2006年第5期40-43,53,共5页
Nonferrous Metals Engineering & Research
关键词
全空气空调
系统分区
精密空调
末端变流量
恒温控制
监控
general air conditioning
systematic zoning
accurate air conditioning
change flowrate at the end
thermostatic control
monitoring