摘要
采用铁炭曝气微电解对炸药废水进行预处理,处理结果表明:当炸药废水调节pH值为2,反应时间2h,物质A投加量2g/L,铁屑与活性炭体积比为1∶1时,进水TOC为2600mg/L,COD为2500mg/L,NH3-N为190mg/L,出水TOC为250mg/L,COD为400mg/L,NH3-N为20mg/L,去除率分别为90.5%、82%和89.6%,BOD5/COD由0.16提高到0.38。
The process of ferric-carbon aeration micro-electrolysis was studied in pre-treatment of dynamite wastewater.Results showed that when condition of ferric-carbon aeration micro-electrolysis was controlled at pH value 2.0,reaction time 2h,dosage of A 2g/L and Fe/C 1:1,the removal efficiency of TOC,CODcr and NH3-N was 90.5%,82% and 89.6% respectively,with BOD5 /CODcr raising from 0.16 to 0.38,and concentration of TOC,CODcr and NH3-N degrading from 2600mg/L to 250mg/L,from 2500mg/L to 400mg/L and from 190mg/L to 20mg/L respectively.
出处
《环境科学与技术》
CAS
CSCD
北大核心
2006年第11期79-81,共3页
Environmental Science & Technology
基金
甘肃省自然科学基金(3SZ042-B25-040)
关键词
铁炭曝气微电解
炸药废水
预处理
去除率
ferric-carbon aeration micro-electrolysis
dynamite wastewater
pre-treatment
removal efficiency