期刊文献+

循环流化床机组风机裕量过大的危害及现场修割措施 被引量:3

Harm of Too Great Reserve Margin of Draft Fans for Circulating Fluidized Bed Unit and On-Site Repairing-Cutting Measures
下载PDF
导出
摘要 文中指出,当前循环流化床锅炉(CFB)风机选型过大是造成一次风机压头偏高、流量偏大、效率低、耗电大、振动大、无法长期安全运行的主要原因。文中提出了对风机叶轮进行现场修割的处理方法,分析了修割的理论依据和特点,介绍了修割后收到的良好效果。 Currently excessively large type selection of draft fans for circulating fluidized bed (CFB) boiler is the main cause fortoo high head of primary air fans,large flow,low efficiency,high electricity consumption,large vibration, being unable to operate safely over a long period of time.The paper puts forward the on-site repairing-cutting handling method of fans' vanes,analyzes the theoretical tasis and features of repairing-cutting.After repairing cutting,good effect has been achieved.
作者 李海奇 杨絮
机构地区 成都电力机械厂
出处 《电力设备》 2006年第11期76-77,共2页 Electrical Equipment
关键词 通风机 风机裕量 修割 CFB机组 coal-fired power plant circulating fluidized bed (CFB) boiler draft fans on site repairing-cutting