期刊文献+

离子阱质谱计的研究现状及其进展 被引量:17

Introduction to Ion Trap Mass Spectrometer
下载PDF
导出
摘要 离子阱质量分析器中离子的运动在数学上可用二阶线性微分方程——Mathieu方程的解来描述,利用离子在Mathieu方程解的稳定性图中所具有的特性,可实现离子的质谱扫描。离子阱质谱计的小型化主要集中在对离子阱质谱计各组成部分(离子源、质量分析器、离子检测、真空系统)的小型化上。随着科技的不断发展,离子阱质谱计体积的小型化,分析对象的不断扩大,仪器性能上实现大质量范围、高分辨率和高灵敏度,以及成本的有效降低等,将是离子阱质谱计相关研究的主要趋势。 Recently, increasing interest in mass spectrometry is focused on miniature instrumentation, especially on the development of miniature ion trap mass spectrometer. The motion of the ions can be expressed by Mathieu Equation and its stability diagram. The mass spectrum of the analyzed ions can be achieved by scanning the amplitude of the RF voltage. The miniaturization of the ion trap mass spectrometer mainly focuses on the miniaturization of components, including ion fountain, mass analyzer, ion detector and vacuum system. With the development of science and technology, the main studies focus on miniaturization, wider applications, higher resolution and wider mass range, rapid analyzing and lower cost.
出处 《质谱学报》 EI CAS CSCD 2006年第4期249-256,共8页 Journal of Chinese Mass Spectrometry Society
基金 国家自然科学基金项目(No.50274070) "十一五"国家科技支撑计划重大项目资助
关键词 离子阱质谱计 质量分析器 小型化 综述 ion trap mass spectrometry mass analyzers miniaturization review
  • 相关文献

参考文献17

  • 1George S. Ion Trap Mass Spectrometry: A Personal Perspeetive[J].J Am Soc Mass Spectrom,2002, 13: 589-596.
  • 2Tabert A M, Griep R J, Guymon A J, et al.High-Throughput Miniature Cylindrical Ion Trap Array Mass Spectrometer[J].Analytical Chemistry, 2003, 75:5 656-5 664.
  • 3宁永成.有机化合物结构鉴定与有机波谱学[M].北京:科学出版社,2005:232—236.
  • 4Philip S H, Wong R, Cooks R G. Ion Trap Mass Spectrometry[J].Encl. Appl. Phys, 1996, 19:289-296.
  • 5Ethan R B, Cooks R G. Miniature Mass Analyzers[J].Mass Speetrom, 2000, 35: 659-671.
  • 6Raymond E M. Quadrupole Ion Trap Mass Spectrometry: a View at the Turn of the Century[J].International Journal of Mass Spectrometry, 2000,200: 285-312.
  • 7Won-Wook L, Pill-Soo K, Mo Y, et al. Characteristics of Cylindrical Ion Trap [J].International Journal of Mass Spectrometry, 2003, 230:25-31.
  • 8Harris W A, Reilly P T A, Whitten W B, et al.Transportable Real-Time Single-Particle Ion Trap Mass Spectrometer[J].Review of Scientific Instruments, 2005, 76:64 102-64 108.
  • 9Griffin M T, MeLuekey S A. A Linear Ion Trap for Biological Agent Detection and Identification[C]. Proceedings of the SPIE-the International Society for Optical Engineering, 2004, 5416 : 33-41.
  • 10Patterson G E, Guymon A J, Riter L S, et al.Miniature Cylindrical Ion Trap Mass Spectrometer[J].Anal. Chem, 2002, 74:6 145-6 153.

共引文献2

同被引文献206

引证文献17

二级引证文献99

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部