建立了高效液相色谱(HPLC)测定强化面粉中维生素A含量的方法。样品用水-甲醇(5+10)提取,提取液用正己烷萃取,萃取液直接用于色谱测定。实验以Chrosorb-60硅胶柱作为分离柱,经对色谱分离条件优化,最佳色谱分离条件为流动相为正己烷-异丙醇-乙酸比例为194:5:1(V/V/V);流速为1.0mL/min;检测波长为326nm。实验结果表明,方法三水平样品回收率(n=5)为98.18%~100.72%;八次重复性实验相对标准偏差(RSD)为1.26%;检出限(S/N=3)为5ng。
A method of determination of vitamin A in fortified flour by (HPLC)has been developed. After the samples were extracted using water-methanol, the extract was filtrated . Vitamin A in the filtrate was extracted in hexane for HPLC measurement,on the Si column with the mobile phase composed of hexane: propanol-[2]: acetic acid solution (194:5: 1, V/V/V). The flow rate of mobile phase was set at 1.0ml/min. The sample was detected by the UV detector at 326nm wavelength. The average recoveries were 98.18% - 100.72%. The relative standard devitations(RSD) was 1.26% (n = 8). The detection limit (S/N = 3) was 5.0ng.
出处
《粮油食品科技》
2006年第6期47-48,共2页
Science and Technology of Cereals,Oils and Foods