地下水流动对地下管群换热器传热的影响分析 被引量:25

HEAT TRANSFER ANALYSIS OF GEOTHERMAL HEAR EXCHANGER UNDER COUPLED CONDUCTION AND GROUNDWATER ADVECTION
下载PDF
导出
摘要 为确定地下水渗流对土壤蓄冷与土壤耦合热泵集成系统中竖直地下管群换热器的影响,该文基于热渗耦合作用下的数学模型,采用整体求解方法求得冬、夏季工况下管内流体、地下埋管换热器及周围土壤的温度场数值解,从而分析了地下水渗流对其传热过程的影响,结果表明地下水运动对原温度场的影响明显,而且越高的地下水流速影响越大。 A comprehensive mathematical model for vertical GHE considering heat conduction and groundwater adveetion was developed using principle of energy conservation. And then a overall solution is utilized to compute the whole temperature contour including fluid in pipe, pipe wall and the surrounding soil. The simulation results indicated that groundwater flow has big influence on original temperature contour clearly, and the big groundwater velocity, the big effect.
作者 范蕊 马最良
出处 《太阳能学报》 EI CAS CSCD 北大核心 2006年第11期1155-1162,共8页 Acta Energiae Solaris Sinica
关键词 土壤蓄冷与土壤耦合热泵集成系统 地下埋管换热器 热渗耦合 数值分析 ISCTS&GSHP geothermal heat exchanger conduction and groundwater advection coupled numerical Analysis
  • 相关文献

参考文献6

  • 1Chiasson A D.Advances in modeling of ground-source heat pump systems[D].Oklahoma State University,1999:24-33.
  • 2Witte H J L,Gelder A J V,Serrao M.Comparison of design and operation of a commercial uk ground source heat pump project[A].1st International Conference on Sustainable Energy Technologies[C],2002.
  • 3Witte H J L.Geothermal Response Testswith Heat Extraction and Heat Injection:Examples of Application in Research and Design of Geothermal Ground Heat Exchangers[A].www.groenholland.nl.2001.
  • 4Yian Gu,Dennis LO'Neal.Development of an equivalent diameter expression for vqertical U-tube used in ground-coupled heat pumps[J].ASHARE Transactions,1998,104:347-355.
  • 5陶文铨.数值传热学(第二版)[M].西安:西安交通大学出版社,2002..
  • 6Xi Chen,PengHan.A note on the solution of conjugate heat transfer problems using SIMPLE-like algorithms[J].International Journal of Heat and Fluid Flow,2000,21:463-467.