期刊文献+

人工晶体检测技术

The Testing Techniques of Intraocular Lenses
下载PDF
导出
摘要 概述了眼睛视觉效果的各项指标以及人工晶体视觉质量的不同检测方法。 This paper outlines kinds of index of eyes' optical effect and some different testing methods of intraocular lenses' optical quality.
出处 《中国医疗器械杂志》 CAS 2006年第6期437-440,共4页 Chinese Journal of Medical Instrumentation
关键词 人工晶体 视觉质量 MTF 波前像差 检测技术 intraocular lenses, optical quality, MTF, wavefront aberrations, testing technique
  • 相关文献

参考文献12

  • 1杨劲松,唐罗生.波前像差及其在白内障手术中的应用[J].国际眼科杂志,2004,4(4):675-679. 被引量:2
  • 2陈宏,程守澄.视觉系统与仪器MTF测试的差异探析[J].应用光学,2002,23(2):45-48. 被引量:3
  • 3Daniele Tognetto,Giorgia Sanguinetti,Paolo Ceccbini,Analysis of the Optical Quality of Intraocular Lenses.IOVS,2004,45(8):2682-2690
  • 4He JC,Marcos S,Webb RH,et al.Measurement of the wave-front aberration of the eye by a fast psychophysical procedure[J].J Opt Soc Am A Opt Image Sci Vis,1998,15(9):2449-2456
  • 5周翔天,瞿佳.波前理论在视觉质量方面的应用及其意义[J].眼视光学杂志,2000,2(3):182-184. 被引量:15
  • 6Liang J,Williams DR.Aberrations and retinal image quality of the normal human eye[J].Jopt Soc AMA,1997,14(11):2873-2883
  • 7Bellucci R,Morselli S,Piers P.Comparison of wavefront aber-ra tions and quality of eyes implanted with five different intraocular lenses.JRefractSurg,2004,20:297-306
  • 8Vilarrodona L,Barrett GD,Johnson B.High-order aberrations in pseudophakia with different intraocular lenses.J Cataract Refract Surg,2004,30:571-575
  • 9马丽,张劲松.波前像差技术在白内障及人工晶状体中的应用[J].国外医学(眼科学分册),2005,29(2):86-89. 被引量:3
  • 10Uchio E,Ohno S,Kusakawa T.Spherical aberration and glare disability with intraocular lenses of different optical design.J Cata ract Refract Surg,1995,21:690-696

二级参考文献58

  • 1Oshika T, Klyce SD, Applegate RA, Howland HC, El Danasoury MA. Comparison of corneal wavefront aberrations after photorefractive keratectomy and laser in situ keratomileusis. Am J Ophthalmol, 1999; 127 ( 1 ): 1-7
  • 2Julia L, Petrauskas JI. A new age for LASIK. Eye Net Magazine Online,2000.Jun-Feb
  • 3Mierdel P, Krinke HE, Wiegand W, Kaemmerer M, Seiler T. Measuring device for determining monochromatic aberration of the human eye. Ophthalmologe , 1997;94(6):441-445
  • 4Howard HC, MacRae SM, Krueger RR. Ophthalmic wavefront sensing. In:Customized Corneal Ablation. Thorofare: SLACK,2001:36-38
  • 5Guirao A, Redondo M, Geraghty E, Piers P, Norrby S, Artal P. Corneal optical aberrations and retinal image quality in patients in whom monofocal intraocular lenses were implanted. Arch Ophthalmol, 2002;120 (9):1143-1151
  • 6Marcos S, Burns SA, Moreno-Barriusop E, Navarro R. A new approach to the study of ocular chromatic aberrations. Vision Res, 1999;39 (26):4309-4323
  • 7ThibosLN, HongX. Clinical applications of the Shack-Hartmann aberrometer. Optom Vis Sci,1999;76(12):817-825
  • 8Kuroda T, Fujikado T, Maeda N, Oshika T, Hirohara Y, Mihashi T. Wavefront analysis in eyes with nuclear or cortical cataract. Am J Ophthalmol,2002; 134:1-9
  • 9Kuroda T, Fujikado T, Maeda N, Oshika T, Hirohara Y, Mihashi T. Wavefront analysis of higher-order aberrations in patients with cataract. J Cataract Refract Surg, 2002;28(3):438-444
  • 10Fujikado T, Kuroda T, Maeda N, Kima, Tano Y, Oshika T, Hirohara Y,Mihashi T. Wavefront analysis of an eye with monocular triplopia and nuclear cataract. Am J Ophthalmol,2004 ;137 (2):361- 363