期刊文献+

Capillary Electrophoresis for the Simultaneous Determination of Metals by Using Ethylenediamine Tetraacetic Acid as Complexing Agent and Vancomycin as Complex Selector

Capillary Electrophoresis for the Simultaneous Determination of Metals by Using Ethylenediamine Tetraacetic Acid as Complexing Agent and Vancomycin as Complex Selector
原文传递
导出
摘要 A new separation system of capillary electrophoresis for the simultaneous determination of metals by using ethylenediamine tetraacetic acid (EDTA) as complexing agent and employing vancomycin as complex selector was described. The Z-shape cell capillary electrophoresis was used to enhance the sensitivity for the determination of the complexes of Cu(Ⅱ), Ni(Ⅱ), Co(Ⅱ) and Fe(Ⅲ) with EDTA. The partial filling method (co-current mode) was used in order to increase the selectivity of the electrophoretic method, meanwhile vancomycin was not present at the detector path during the detection of metal-EDTA complexes. The vancomycin concentration, phosphate concentration and pH of the buffer strongly influenced mobility, resolution and selectivity of the studied analytes. Under the optimal condition, the relative standard deviations (n=5) of the migration time and the peak area were less than 3.14% and 7.35%, respectively. Application of the Z-shape cell capillary electrophoresis method with UV detection and vancomycin loading led to the reliable determination of these metal ions in tap water and the recoveries were 97%-101%. The detection limits based on a signal to noise ratio of 3 : 1 were found in the range of 2-10 μg·L^-1. A new separation system of capillary electrophoresis for the simultaneous determination of metals by using ethylenediamine tetraacetic acid (EDTA) as complexing agent and employing vancomycin as complex selector was described. The Z-shape cell capillary electrophoresis was used to enhance the sensitivity for the determination of the complexes of Cu(Ⅱ), Ni(Ⅱ), Co(Ⅱ) and Fe(Ⅲ) with EDTA. The partial filling method (co-current mode) was used in order to increase the selectivity of the electrophoretic method, meanwhile vancomycin was not present at the detector path during the detection of metal-EDTA complexes. The vancomycin concentration, phosphate concentration and pH of the buffer strongly influenced mobility, resolution and selectivity of the studied analytes. Under the optimal condition, the relative standard deviations (n=5) of the migration time and the peak area were less than 3.14% and 7.35%, respectively. Application of the Z-shape cell capillary electrophoresis method with UV detection and vancomycin loading led to the reliable determination of these metal ions in tap water and the recoveries were 97%-101%. The detection limits based on a signal to noise ratio of 3 : 1 were found in the range of 2-10 μg·L^-1.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2006年第12期1747-1753,共7页 中国化学(英文版)
基金 Project supported by the National Natural Science Foundation of China (Nos. 20437020 and 20575008) and the Post Doctoral Research Scholarship of Department of Chemistry, Tsinghua University.
关键词 Z-shape cell capillary electrophoresis VANCOMYCIN metal ion ethylenediamine tetraacetic acid Z-shape cell capillary electrophoresis, vancomycin, metal ion, ethylenediamine tetraacetic acid
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部