期刊文献+

Imaging Array SPR Biosensor Immunoassays for Sulfamethoxazole and Sulfamethazine

Imaging Array SPR Biosensor Immunoassays for Sulfamethoxazole and Sulfamethazine
下载PDF
导出
摘要 A homemade array surface plasmon resonance (SPR)-based imaging biosensor was used to develop sensitive and fast immunoassays to determine sulfamethoxazole (SMOZ) and sulfamethazine (SMT) in buffer. Two conjugations of sulfonamide-bovine serum albumin (BSA) were separately immobilized on two different rows of the array chip with one row as reference. The immobilization was carried out in the instrument to monitor the quantity of the conjugations immobilized. The antibody mixed with the sulfonamide in the buffer was injected over the surface of the chip to get a relative response which was inversely proportional to the concentration of the sulfonamide in the PBS buffer. Two calibration curves were constructed and the limit of detection for sufamethoxazole in buffer was 3.5 ng/mL and for sulfamethazine 0.6 ng/mL. The stability and specificity of the antibody were also studied. The monoclonal antibody did not bind with BSA. A homemade array surface plasmon resonance (SPR)-based imaging biosensor was used to develop sensitive and fast immunoassays to determine sulfamethoxazole (SMOZ) and sulfamethazine (SMT) in buffer. Two conjugations of sulfonamide-bovine serum albumin (BSA) were separately immobilized on two different rows of the array chip with one row as reference. The immobilization was carried out in the instrument to monitor the quantity of the conjugations immobilized. The antibody mixed with the sulfonamide in the buffer was injected over the surface of the chip to get a relative response which was inversely proportional to the concentration of the sulfonamide in the PBS buffer. Two calibration curves were constructed and the limit of detection for sufamethoxazole in buffer was 3.5 ng/mL and for sulfamethazine 0.6 ng/mL. The stability and specificity of the antibody were also studied. The monoclonal antibody did not bind with BSA.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第11期1481-1484,共4页 中国化学快报(英文版)
基金 The authors greatly acknowledge the financial support from the National Natural Science Foundation of China(No.60027001 and 60302003) the National High Technology Research and Development program of China(No.20060100Z3044).
关键词 IMAGING surface plasmon resonance BIOSENSOR reference surface sulfamethoxazole sulfamethazine. Imaging, surface plasmon resonance, biosensor, reference surface, sulfamethoxazole,sulfamethazine.
  • 相关文献

参考文献6

  • 1A. Sternesjo,,C. Mellgren,L. Bjork. Anal Biochem . 1995
  • 2W. Haasnoot. Analytica Chimica Ac/a . 2003
  • 3B. Johnsson,,L. Stefan,G. Lindqust. Anal Biochem . 1991
  • 4D. F. Cui,L. F. Zhou. National Patent,ZL98102366 5 .
  • 5D. F. Cui,X. M. Li,H. Y. Cai. Xiandai Kexue Yiqi (Modem Scientific Instruments . 2001
  • 6D. F. Cui,Y. J. Wang,H. Y. Cai. The Development of Natural Science . 2003