摘要
针对自行设计的气体爆炸试验装置中的空气加热管路部分进行了压力损失的计算,并进行了实验验证,通过实验验证该管路达到了设计要求。
The loss of air - heated pipe pressure in the gas explosion experimental equipment designed by our deqartment is calculated and it is also proved from experiments that this pipe meets the design requirements.
出处
《工业安全与环保》
2006年第12期5-6,共2页
Industrial Safety and Environmental Protection
关键词
气体爆炸
加热管
压力损失
gas explosion heated pipe loss of pressure