摘要
结合现场中试探讨了超滤作为反渗透预处理工艺的可行性,确定了超滤工艺处理某火电厂废水的基本参数,研究了超滤膜的恢复及效果,并且提出了系统设计的相关建议,对工业系统设计具有指导意义。
The feasibility of ultra-filtration for pretreatment technics of reverse osmosis was discussed by local industria experiment. The basic parameters of some power plants sewage treatment using ultra-filtration technology were analyzed, the measures of ultra-filtration membrane renew and its effect were researched. The correlative advices of system design were put forward, which had directive meaning for practical system design.
出处
《电力环境保护》
2006年第6期54-56,共3页
Electric Power Environmental Protection
关键词
超滤膜
火电厂废水
工业性试验
ultra-filtration membrane
power plant sewage
industrial experiment