期刊文献+

强酸性电解水复用透析器对透析膜透析效率的影响 被引量:2

Influence of Reprocessing Dialysers with Electrolyzed Strong Acid Aqueous Solution on Dialysis Efficiency
下载PDF
导出
摘要 目的观察强酸性电解水消毒复用三醋酸纤维透析器对小分子溶质尿素清除指数(KT/V)利尿素清除率(urearemovalratio,URR)的影响,以及扫描电镜下不同复用次数透析膜内纤维蛋白假膜的形成和变化,探讨强酸性电解水复用透析器对尿素清除效率的影响。方法14例规律血液透析病人随机分为2组,每组7例,A组为强酸性电解水复用实验组,B组为过氧乙酸复用对照组。两组分别于复用的0、1、3、5次观察各指标。结果两组间不同复用次数的KT/V、URR相比无显著性差异。扫描电镜下过氧乙酸复用第4次可见少量纤维蛋白沉积,两种消毒剂复用第5次透析膜内均见纤维蛋白假膜形成,强酸性电解水复用者纤维蛋白假膜沉积累及的纤维束数量明显少于过氧乙酸复用者,且假膜的厚度薄得多。结论强酸性电解水消毒复用5次透析器对尿素的透析效率无影响。 Objective To investigale lhe dialysis efficiency of reprocessing cellulose triacetate dialysers with electrolyzed strong acid aqueous solution. Methods 14 patients with chronic renal failure on regular hemodialysis treatment were randomly allocated to two groups. The dialyzers of Group A (n=7) was reprocessed with electrolyzed strong acid aqueous solulion and Group B (n=7) with peracetic acid as a control. Urea removal (expressed as KT/V, urea reduction ralio-URR) were observed on various reuse. The scanning electrono-graphs of various reprocessed membranes were also observed. Results There was no difference among the values of KT/V and URR on various reuses with the both disinfectanls. Under the scanning electron microscope deposiled layers of proteins were seen on the dialysis membranes, The number of deposited layers of proteins involving the cellulose bundles in group A was less than group B. Conelusions There was no influence of reprocessing dialyzers with electrolyzed strong acid aqueous solution on dialysis efficiency of urea.
出处 《海南医学》 CAS 2007年第1期103-104,共2页 Hainan Medical Journal
关键词 血液透析 强酸性电解水 复用 尿素消除指数 尿素清除率 扫描电镜 Hemodialysis Electrolyzed strong acid aqueous solution Reprocessing dialyzer KT/V URR Scanning electron microscope
  • 相关文献

参考文献10

  • 1姜惠芳,刘子栋.强酸性电解水复用透析器的可行性研究[J].海南医学,2006,17(11):63-65. 被引量:1
  • 2Teruel JI,Fernandez Lucas M,Lopez Sanchez J et al.Relationship between the 1993 Daugirdas kt/v method and other methods to calculate the dialysis dose.Nefrologia,2000,20:72-78.
  • 3Blake PG. Practical guide to measuring adequacy of dialysis, Adv Ren Replace Ther,1999,6:80-84.
  • 4Rockel A. Hertel J, Fiege P, et al. Permeability and secondary membrane formation of a high flux polysulfone hemofilter. Kidney Int,1986.30:429.
  • 5Westhuyzen J, Foreman K. Effect of dialyzer membrane reuse on serum beta-2 microglobulin concentration in hemodialysis patietas.Kidney Int,1991,40:560(abstr).
  • 6Richard A,Sherman ,Ronald P Cody,Mary Ellen Rogers,et al.The effect of dialyzer reuse on dialysis delivery.Am J Kidney Dis,1994,24(6):924-926.
  • 7John K Leypldt,Alfred K Cheung,R Barry Decter.Effect of hemodialyzer reuse:dissociation between clearances of small and large solutes.Am J Kideny Dis,1998.32(2):295-301.
  • 8Rosemary Ouseph,Brian P Smith,Richard A.Maimaining blood compartment volume in dialyzers reprocessed with peracetic acid maintains Kt/V but not β 2-microglobulin removal.Am J Kidney Dis,1997,30(4):501-506.
  • 9Ng-YY,Yang-AH,Wong-LC,et al.Dialyzer reuse:interaction between dialyzer membrane,disinfectant(formalin),and blood during dialyzer reprocessing.Artif Organs,1996,20(1):53-5.
  • 10Meri K Scott,Bruce A Mueller,Kevin M Sowinski, et al.Dialyzer-dependent changes in solute and water permeability with bleach reprocessing.Am J Kidney Dis ,1999,33(1):87-96.

二级参考文献19

  • 1A.K.Cheung and H.Lemke.Criteria and standardization for biocompatibilitry.Nephrol Dial Transplant,1994,9[Suppl.2]:72-76.
  • 2Yoshihiro Inoue,Shigeatsu Endo,Koryo Kondo,et al.Trial of electrolyzed strong acid aqueous solution lavage in the treatment of peritonitis and intrapeitoneal abscess.Artif Organs,1997,21(1):28-31.
  • 3松本洋,河野雅弘.强酸性电解水の基础知识.う株式会社,1997.
  • 4Chizzonite R,Truitt T,Kilian Pi,et al Two high affinity interleukin I receptors repreaent separate gene products Proc Natl Acad Sci USA,1989,868029-8033.
  • 5Philippe Zaoui and Raymond M.Hakin.The effects of the dialysis membrane on cytokine release.J Am Soc Nephrol,1994,4:1711-1718.
  • 6Tokars JI,Alter M J,Favao MS,et al.National surveillance ofhemodialysis associated diseases in the United States,1990.Am Soc Artiflntem Org J,1993,39:71-80.
  • 7S.Shaldon.Reuse of haemodialysers,Nephrol Dial Transplant,1994,9:1226-1227.
  • 8Nuhad Imail,Bryan N:Becker,Raymond M.Hakim.Water treatment for hemodyalysis.Am J Nephrol,1996,16:60-72.
  • 9Patricia Y.Schoenfeld.The technology of dialyzer reuse.Semi Nephroi,1997,17 (4):321-330.
  • 10Task Force on Reuse of Dialyzers,Council on Dialysis,National Kidney Foundation.National kidney foundation report on dialysis reuse.Am.J Kidney Dis,1997,30(6):859-871.

同被引文献70

引证文献2

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部