期刊文献+

泵站水泵蜗形进水池的试验研究 被引量:7

Experimental investigation on volute intake sump of pumping stations
下载PDF
导出
摘要 火电厂冷却水泵进水池通常采用矩形进水池,通过分析表明矩形进水池的流态并非十分理想,水力设计尚需改进。因此提出蜗形进水池方案代替矩形进水池,并且通过模型试验来研究两类进水池水力性能的优劣。试验中采用美国进水设计标准中旋度计测量涡角检验进水性能的方法。试验结果表明蜗形进水池优于矩形进水池。研究结论和传统的泵装置性能试验结论一致,表明通过涡角检验进水性能的方法是可靠正确的。 The rectangle intake sumps are usually used for the intake of thermal power plant. However, the flow pattern of which is not good, its design needs to be improved. The volute intake sump is substituted for the rectangle intake sump. The hydraulic performance test between the volute intake sump and the rectangle intake sump are conducted by model experiment. Vortex angles are measured by the swirlmeter and are used for checking the hydraulic performance of intake sump. Model experiment results indicate that the volute intake sump is better than the rectangle intake sump and the method of experimental investigation with vortex angle is reliable and correct.
出处 《水力发电学报》 EI CSCD 北大核心 2006年第6期145-148,共4页 Journal of Hydroelectric Engineering
基金 江苏高校省级重点实验室开放课题(KJS03087)
关键词 水力学 进水池 试验研究 旋度计 泵站 hydraulics intake sump experimental investigation swirlmeter pumping stations
  • 相关文献

参考文献6

二级参考文献13

  • 1徐宇 吴玉林 等.水泵吸水池内紊流及旋涡的数值模拟.中国工程热物理学会流体机械学术会议论文集[M].北京,2000,10..
  • 2刘清朝,水利学报,1993年,1期
  • 3钱义达,江苏农学院学报,1989年,10期
  • 4皮积瑞,水泵技术,1989年,3期
  • 5储训,中小型抽水站设计与图集,1988年
  • 6关醒凡,泵的理论与设计,1987年
  • 7黄林泉,水泵进水池模型试验法,1986年
  • 8团体著者,抽水站,1986年
  • 9马铁犹,计算流体动力学,1986年
  • 10刘竹溪,水泵及水泵站(第2版),1986年

共引文献46

同被引文献51

引证文献7

二级引证文献60

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部