摘要
提出了热泵耗煤当量的概念。以邯郸地区为例,分析了电力驱动热泵供热技术(以土壤源热泵为例)替代锅炉房供热后,供暖季单位住宅建筑面积锅炉房的耗煤量与土壤源热泵耗煤当量的差别。计算出供暖季单位住宅建筑面积温室气体CO2排放的减少量。分析了影响温室气体减排量的几个因素。
The concept of heat pump coal consumption equal quantity of coal consumption between heating boiler and heat pump-take geothe was brought forward to analyzing the difference rmal heat pump for example-of per heating units of the resident building in Handan climate. When the heating boiler was substituted for heat pump, the emission reduction of Green House Gas CO2 of per heating units of the resident building was calculated and several factors that influence the emission reduction of GHG was simply analyzed.
出处
《河北建筑科技学院学报》
2006年第4期48-50,共3页
Journal of Hebei Institute of Architectural Science & Technology
基金
河北省科学技术研究与发展计划项目(06276903D-2)
关键词
土壤源热泵
温室气体
减排
耗煤当量
ground-source heat pump
Greenhouse Gas
emission reduction
coal consumption equal quantity