摘要
针对凝结水泵出现的汽蚀现象,从凝结水泵结构、低压加热器的泄漏、回水加热流程几个方面进行了逐步检查与分析,找出了凝结水泵汽蚀的根源,采取了相应的措施。
In the light of cavitation phenomenon in a condensate pump, the structure of the condensate pump, checked and analyzed. relevant measures were leakage of low-pressure heater and backwater heating process were The cavitation causes of the condensate pump were found out and the adopted.
出处
《冶金动力》
2006年第6期50-51,共2页
Metallurgical Power
关键词
凝结水泵
汽蚀
低压加热器
泄漏
condensate pump
cavitation
low-pressure heater
leakage