期刊文献+

连续流动式聚合酶链式反应生物芯片/微装置中脱氧核糖核酸样品的驱动控制技术进展

PROGRESS OF ACTUATION CONTROL TECHNIQUE OF SAMPLES IN MICRO-DEVICE OF CONTINUOUS-FLOW POLYMERASE CHAIN REACTION BIOCHIP
下载PDF
导出
摘要 介绍国内外连续流动式聚合酶链式反应生物芯片/微装置中脱氧核糖核酸样品的驱动控制技术进展,主要包括恒流泵(注射泵驱动和蠕动泵驱动)、旋转泵驱动、磁流体动力驱动以及自然对流驱动等。并对这几种驱动方式的优缺点作简要的讨论(引用文献43篇)。 A review of the recent progress of actuation control technique of DNA samples in micro-device of continuous-flow polymer ase chain reaction biochip, Covering mainly the years from 1985 to 2006 was presented in this paper, pertaining especially to the actuation by constant flow pumps (actuated with iniection pump and peristaltic pump), by rotary pump, and magnetohydrodynamic actuation and natural convection actuation; and a brief discussion on the merits and defects of various ways of actuation was also given (43 ref. cited).
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2006年第12期1063-1068,共6页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基金 国家自然科学基金资助项目(50476088)
关键词 连续流动式PCR生物芯片/微装置 DNA样品 驱动控制技术 Continuous-flow polymerase chain reaction Bio-chip DNA sample Actuation control technique
  • 相关文献

参考文献43

  • 1Saiki R K,Scharf S,Faloona F,et al.Science[J],1985,230.:1350.
  • 2Wittwer C T,Fillmore G C,Garling D J.Anal Biochem[J],1990,186:328.
  • 3Northrup M A,Ching M T.Proceeding of the 7th International Conference on Solid State Sensors and Actuators[C].Japan:Yokohama,1993:924.
  • 4Liu J,Enzelberger M,Quake S.Electrophoresis[J],2002,23:1531.
  • 5Kricka L J,Wilding P.Anal Bioanal Chem[J],2003,377:820.
  • 6Zhang Qintao,Wang Wenhui,Zhang Hongshen,et al.Sens Actuat B[J],2002,82:75.
  • 7Larzul M D.Apparatus for repeated automatic execution of a thermal cycle for treatment of samples:US patent 5176203[P].1993-05-01.
  • 8Nakano H,Matsuda K,Yohda M,et al.Biosci Biotechnol Biochem[J],1994,58(2):349.
  • 9Kopp M U,de Mello A J,Manz A.Science[J],1998,280:1046.
  • 10Yu Xiaomei,Zhang Dacheng,Li Ting,et al.Sens Actuat A[J],2003,108:103.

二级参考文献10

  • 1Northrup M A, Ching M T, White R M, et al. DNA Ampliaction in a microfabricated reaction chamber, leansducers'93[A], in: Proceedings of the 7th International Conference on Solid State Sensors and Actuators [ C ].Yokohama, Japan, June 1993, 924-926.
  • 2Lin Yu - Cheng. A rapid micro - polymerase chain reaction system for hepatitis C virus amplification[J]. Sensors and Actuators, 2000, B71:127 - 133.
  • 3Lin Yu - Cheng. Simulation and experimental validation of micro polymerase chain reaction chips[J]. Sensors and Actuators, 2000, B71:2 - 8.
  • 4Martin U Kopp, Andrew J de Mello, Anderas Manz.Chemical Amplification: Continuous - Flow PCR on a chip[J]. Sdence, 1998, 280 : 1046 - 1048.
  • 5Ivonne Schneegaβ, Johann Michael Koehler. Flow -through polymerase chain reaction in chip thermocyclers[J].Reviews in Molecular Bioteclmology, 2001, 82 : 101 -121.
  • 6Zhao Zhan,Proc 1st Annual Int IEEEE MBS Special Topic Conference on Microtechnologies in Medicine Biology,2000年,25页
  • 7Fritz J,Science,2000年,288卷,316页
  • 8陶永华.新型 PID 控制及其应用──第四讲 模糊 PID 控制[J].工业仪表与自动化装置,1998(1):57-62. 被引量:44
  • 9沙占友,唱春来,范志广.由DS1820组成的单线数字温度计原理与应用[J].电测与仪表,1999,36(2):25-28. 被引量:24
  • 10赵湛,崔大付.基因传感器[J].电子产品世界,2000,7(8):63-63. 被引量:7

共引文献18