期刊文献+

单边干涉图的数据处理方法研究 被引量:36

Some Aspects of the Data Processing of the Single Sided Interferogram
下载PDF
导出
摘要 干涉成像光谱仪干涉图的采样方式一般有两种,即单边采样和双边采样,单边采样干涉图往往保留零光程差附近的部分“短双边”采样数据以利于数据处理·本文对空间调制干涉成像光谱仪不同干涉图采样方式下的光谱复原方法进行了研究,讨论了空间调制干涉成像光谱仪单边干涉图的切趾与相位修正,提出了更为合理和准确的方法.研究发现,合理设置短双边数据在减小仪器的原始数据量的同时,能够保证复原光谱的准确度· There are two types of the interferogram of spatially modulated imaging Fourier transform spectrometer(SMIFTS), namely single sided and double sided. In the case there are usually a small portion of sampling points around the zero pat correction. In this paper, some aspects of data processing of the single sided detail and b condit while of single sided interferogram h difference(ZPD) for phase interferogram are discussed in including apodization and phase correction. A novel weighting and apodization method is proposed etter recovered spectra are obtained by computer simulation. It is found that under adequate ions,the reconstructed spectra from single sided interferogram are good enough for application mean the raw data rate is smaller than double sided sampling.
作者 相里斌 袁艳
出处 《光子学报》 EI CAS CSCD 北大核心 2006年第12期1869-1874,共6页 Acta Photonica Sinica
基金 国家自然科学基金(60532070)资助
关键词 空间调制干涉成像光谱仪 单边干涉图 切趾 相位修正 Spatially modulated imaging fourier transform spectrometer (SMIFTS) Single sided interferogram Apodization Phase correction
  • 相关文献

参考文献15

  • 1Hammer P D,Valero F P J,Peterson D L.An imaging interferometer for terrestrial remote densing.Proc of SPIE,1993,1937:244~255
  • 2Rafert J B,Sellar R G,Blatt J H.Monolithic Fourier transform imaging spectrometer.Appl Opt,1995,34(31):7228~7230
  • 3Smith W H,Hammer P D.Digital array scanned interferometer:sensors and results.Appl Opt,1996,35(16):2902~2909
  • 4相里斌.干涉成像光谱技术研究.博士后研究工作总结报告.西安:中国科学院西安光机所,1995.8~1997.8
  • 5相里斌,赵葆常,薛鸣球.空间调制干涉成像光谱技术[J].光学学报,1998,18(1):18-22. 被引量:86
  • 6Otten III L J,Butler E W,Rafert J B.The design of an airborne Fourier transform visible hyperspectral imaging system for light aircraft environment remote sensing.SPIE,1995,2480:418
  • 7Otten III L J,Sellar R G,Rafert J B.MightySat II.1 Fourier transform hyperspectral imager payload performance.Proc of SPIE,1995,2583:566~575
  • 8Xiangli Bin,Gao Zhan,An Baoqing.Static imaging Fourier transform spectrometer.SPIE,1998,3502:30~34
  • 9Griffiths P R.Fourier transform infrared spectrometry.NewYork:Wiley Interscience Publication,1986
  • 10Bell R J.Introductory fourier transform spectroscopy.Beijing:Academic Press,1972

二级参考文献4

  • 1[2]Inoue T, Itoh K, Ichioka Y. Fourier transform spectral imaging near the image plane.Optics Letters, 1991,16(12):934~936
  • 2[3]Mailhes C, Vermande P, Castanie F. Spectral image compression.J Optics (Paris), 1990,21(3):121~132
  • 3[5]Max J.Quantizing for the minimum distortion.IRE Trans Inform Theory,IT-6:7~12
  • 4[6]http://www.s2.chalmers.se/undergraduate/course0001/eit0.../Designcriteriaoptim-al.htm