期刊文献+

有源转发器延时对SAR定标测量的影响 被引量:1

Effect on SAR Calibration from Transponder Time-Delay
下载PDF
导出
摘要 该文研究了有源转发器延时对距离向压缩信号、方位向压缩信号幅度和相位的影响;通过数据仿真,分析和讨论了不同分辨率、不同时延长度的情况下,有源转发器延时对点目标成像位置、主瓣及旁瓣的影响,并给出有源转发器时延设置时需要考虑的因素。 The effect of transponder time-delay on amplitude and phase of both range-compressed and azimuth-compressed signal are researched. Through simulation, the impact of transponder time-delay on imaging location, main-lobe, side-lobe of point target pulse response are analyzed and discussed under different resolution, different length of time-delay, Besides, the factors which need to be taken into consideration during time-delay setting are presented.
作者 耿波 洪峻
出处 《电子与信息学报》 EI CSCD 北大核心 2006年第12期2240-2243,共4页 Journal of Electronics & Information Technology
关键词 SAR定标 有源转发器 延时 点目标 SAR calibration, Transponder, Time-delay, Point target
  • 相关文献

参考文献4

  • 1Freeman A.SAR calibration:An overview.IEEE Trans.on Geosci Remote Sensing[J],1992,30(6):1107-1121.
  • 2Masanobu Shimada,Hiromi Oaku,Masao Nakai.SAR calibration using frequency tunable active radar calibrators[J].IEEE Trans.on Geosci Remote Sensing,1999,37(1):564-573.
  • 3Curlander J C,McDonough R N.Synthetic Aperture RADAR:System and Signal Processing[M].New York:wiley-interscience publication,1991:322-327.
  • 4刘永坦.雷达成像技术[M].哈尔滨:哈尔滨工业大学出版社,2001..

共引文献25

同被引文献8

  • 1Shimada M, et al.. PalSAR radiometric and geometric calibration[J]. IEEE Transactions on Geoscience and Remote Sensing, 2009, 47(12): 3915-3932.
  • 2Schwerdt M, et al.. Monostatic calibration of both TANDEM-X satellites[C]. IGARSS, Hawaii, USA, July 25-30, 2010: 2636-2639.
  • 3Zakharov A I and Sorochinskii M V. External calibration of a polarimetric synthetic aperture radar for a limited number of types of reference reflectors[J]. Journal of Communications Technology and Electronics, 2010, 55(10): 1102-1107.
  • 4Touzi R and Hawkins R K. On the use of transponder for high precision assessment & calibration of polarimetric radaxsat-2. PolinSAR'11, Frascatti, Jan. 24, 2011: 1-38.
  • 5Doring B, Schwerdt M, and Bauer R. TerraSAR-X calibration ground equipment[C]. WFMN07, Conference of ITG - Commission on Wave Propagation, Dresden, Gerraany 2007, II _C4: 86-90.
  • 6Snoeij P, et al.. Transponder development for Sentinel-1[C]. EUSAR, Aachen, Germany, June 7-10, 2010: 354-357.
  • 7Doring B J, et al.. Highly accurate calibration target for multiple mode SAR systems[C]. EUSAR, Aachen, Germany, June 7-10, 2010: 354-357.
  • 8张云华.现代雷达理论与技术讲义.中国科学院研究生院,2010.

引证文献1