期刊文献+

空气源热泵制冷热回收机组的技术可行性 被引量:3

The Technical Feasibility of Air-Source Heat Pump Heat Recovery Unit
下载PDF
导出
摘要 通过对一台普通的空气源热泵进行热回收改造,利用回收的热量加热生活热水。改造后的机组在实验台上进行了全年运行工况测试,通过对机组改造前后运行工况的分析对比,提出了带热回收装置的热泵是一种节能的空调热水机组,并对机组在冬季的运行过程中可能出现的问题作了说明。 A common air-source heat pump is reconstructed with a heat-recovery device installed into it to heat up living-water with the recovered heat. The performance of the reconstructed heat pump is examined, on a yearly basis, in the following experiments presented in this paper. This paper also presents the comparison of the performance of the heat pump before and after the reconstruction, comes to the conclusion that the heat pump, equipped with a heat recovery device, is an energy-saving unit capable of both air-conditioning and living-water heating, and gives an account of the performing problem that may occur in winter.
机构地区 同济大学
出处 《能源技术》 2006年第6期264-267,共4页 Energy Technology
关键词 冷凝热回收 空气源热泵 热回收供热量 性能系数COP condensing-heat recovery air-source heat pump recovered heat coefficient of performance
  • 相关文献

参考文献5

二级参考文献4

共引文献6

同被引文献21

  • 1李舒宏,武文彬,张小松,殷勇高.太阳能热泵热水装置试验研究与应用分析[J].东南大学学报(自然科学版),2005,35(1):82-85. 被引量:42
  • 2毕晓平,宋春光,宋子彦.采用空气源热泵热回收机组节能效果分析[J].城市管理与科技,2005,7(2):77-79. 被引量:2
  • 3王巧丽,孙淑凤,王立.双热源空调-热水器一体机冬季制热的实验研究[J].低温与超导,2007,35(3):262-265. 被引量:2
  • 4Chyng J P, Lee C P, Huang B J. Performance analysis of a solar-assisted heat pump water heater[J]. Solar Energy, 2003, 74(1): 33-44.
  • 5Hawlader M N A, Chou S K, Jahangeer K A, et al. Solar- assisted heat-pump dryer and water heater[J]. Applied Energy, 2003, 74 (1-2) :185-193.
  • 6V D Baxter, E E.Comparison of Field Performance of a High Efficiency Heat Pump with and without a Desuperheater Water Heater[J]. ASHRAE Trans, 1984(2):180-190.
  • 7Alex H W Lee, Jerold W Jones. Thermal performance of a residential desuperheater/water heater system[J]. Energy Conversion and Management, 1996,37(4):389-397.
  • 8A H Fanney. Performance of faresidential desuperhearer ASHRAE Trans[J]. 1994, 3588:489-499.
  • 9M L D. Valentine desuperheater water-heater and air- to-air heat pump system., representative pereormance data[J]. ASHRAE Trans, 1996, 3430:417-427.
  • 10M olszewski. Economic Viability of Heat Pump Desuperheaters for Supplying Domestic Hot Wateg[J]. ASHRAE Trans, 1984, 4:169-179.

引证文献3

二级引证文献6